Literature DB >> 16408266

Characterizing radial undersampling artifacts for cardiac applications.

Dana C Peters1, Pratik Rohatgi, René M Botnar, Susan B Yeon, Kraig V Kissinger, Warren J Manning.   

Abstract

The undersampled radial acquisition has been widely employed for accelerated (by a factor R = N(r)/N(p)) cardiac imaging, but the resulting reduction in image quality has not been well characterized. This investigation presents a method of measuring these artifacts through synthetic undersampling of high SNR images (SNR > or = 30). After validating the method in phantoms, the method was applied to a study of short-axis, long-axis, and coronary MRI imaging in healthy subjects. For 60 projections (60 N(p)), the total artifact is approximately 10% for short and long-axis imaging (R = 2.1) and approximately 15% for coronary MRI (R = 3.7). For 60 N(p), the SD of artifact in the region of the heart is 2% for short- and long-axis imaging (R = 2.1) and 3.5% for coronary MRI (R = 3.7). The artifact content is less in the region of the heart than in the periphery. The artifact is very reproducible among subjects for standard views. A study of coronary MRI at progressively fewer projections (at constant scan time) showed that right coronary MRI images were acceptable if total artifact was <6.5% of image content (N(p) > 120, R = 2.1). Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16408266     DOI: 10.1002/mrm.20782

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

2.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

3.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

Review 4.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

5.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

6.  Error decomposition for parallel imaging reconstruction using modulation-domain representation of undersampled data.

Authors:  Yu Li
Journal:  Quant Imaging Med Surg       Date:  2014-04

7.  Three-dimensional through-time radial GRAPPA for renal MR angiography.

Authors:  Katherine L Wright; Gregory R Lee; Philipp Ehses; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

8.  Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging.

Authors:  Jaime S Robb; Chenxi Hu; Dana C Peters
Journal:  Magn Reson Med       Date:  2019-10-12       Impact factor: 4.668

9.  Machine Learning for Rapid Magnetic Resonance Fingerprinting Tissue Property Quantification.

Authors:  Jesse I Hamilton; Nicole Seiberlich
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2019-09-11       Impact factor: 10.961

10.  Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR).

Authors:  Hyun J Jeong; Ty A Cashen; Michael C Hurley; Christopher Eddleman; Christopher Getch; H Hunt Batjer; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.