Literature DB >> 1640761

Triaxial force transducer for investigating stresses at the stump/socket interface.

R B Williams1, D Porter, V C Roberts, J F Regan.   

Abstract

Although normal pressures at the stump socket interface of the lower-limb amputee have been investigated, little is known about the shear stresses that also occur. Studies suggest that the combination of both shear and normal stresses significantly exacerbates discomfort and vascular and tissue damage. A means of simultaneously measuring normal and shear stresses will aid in the investigation and improvement of prosthetic fit. A miniature triaxial force transducer (4.9 x 16 mm diameter) has been developed which can be recessed into the socket wall. The principle of operation, construction, performance and limitations of the device are described. Preliminary measurements of the interface stress variations over the gait cycle in a supra-condylar PTB socket are presented. These show clear differences in the stress patterns present when two different prosthetic feet are used.

Entities:  

Mesh:

Year:  1992        PMID: 1640761     DOI: 10.1007/bf02446199

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Evaluation of pressure as a factor in the production of ischial ulcers.

Authors:  M KOSIAK; W G KUBICEK; M OLSON; J N DANZ; F J KOTTKE
Journal:  Arch Phys Med Rehabil       Date:  1958-10       Impact factor: 3.966

2.  Stump-socket pressure in lower extremity prostheses.

Authors:  F Appoldt; L Bennett; R Contini
Journal:  J Biomech       Date:  1968-12       Impact factor: 2.712

3.  Shear vs pressure as causative factors in skin blood flow occlusion.

Authors:  L Bennett; D Kavner; B K Lee; F A Trainor
Journal:  Arch Phys Med Rehabil       Date:  1979-07       Impact factor: 3.966

4.  Pressure variation in the below-knee, patellar tendon bearing suction socket prosthesis.

Authors:  J R Pearson; S Grevsten; B Almby; L Marsh
Journal:  J Biomech       Date:  1974-11       Impact factor: 2.712

5.  Tangential pressure measurements in above-knee suction sockets.

Authors:  F A Appoldt; L Bennett; R Contini
Journal:  Bull Prosthet Res       Date:  1970

6.  Effect of liner materials on interface pressures in below-knee prostheses.

Authors:  W A Sonck; J L Cockrell; G H Koepke
Journal:  Arch Phys Med Rehabil       Date:  1970-11       Impact factor: 3.966

7.  Total surface bearing self suspending above-knee sockets.

Authors:  R G Redhead
Journal:  Prosthet Orthot Int       Date:  1979-12       Impact factor: 1.895

8.  Forces under the foot.

Authors:  J P Pollard; L P Le Quesne; J W Tappin
Journal:  J Biomed Eng       Date:  1983-01

9.  Dynamic pressure measurements at the interface between residual limb and socket--the relationship between pressure distribution, comfort, and brim shape.

Authors:  M Naeff; T van Pijkeren
Journal:  Bull Prosthet Res       Date:  1980
  9 in total
  5 in total

Review 1.  Interface mechanics in external prosthetics: review of interface stress measurement techniques.

Authors:  J E Sanders
Journal:  Med Biol Eng Comput       Date:  1995-07       Impact factor: 2.602

Review 2.  Transducers for foot pressure measurement: survey of recent developments.

Authors:  J Cobb; D J Claremont
Journal:  Med Biol Eng Comput       Date:  1995-07       Impact factor: 2.602

3.  Textile-based Pressure Sensors for Monitoring Prosthetic-Socket Interfaces.

Authors:  Jordan Tabor; Talha Agcayazi; Aaron Fleming; Brendan Thompson; Ashish Kapoor; Ming Liu; Michael Lee; He Helen Huang; Alper Bozkurt; Tushar Ghosh
Journal:  IEEE Sens J       Date:  2021-01-21       Impact factor: 3.301

4.  Investigation of Regression Methods for Reduction of Errors Caused by Bending of FSR-Based Pressure Sensing Systems Used for Prosthetic Applications.

Authors:  Chakaveh Ahmadizadeh; Carlo Menon
Journal:  Sensors (Basel)       Date:  2019-12-13       Impact factor: 3.576

Review 5.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.