Literature DB >> 16400206

A new approach for non-intrusive monitoring of blood pressure on a toilet seat.

Jung Soo Kim1, Young Joon Chee, Ju Wan Park, Jin Wook Choi, Kwang Suk Park.   

Abstract

Pulse arrival time (PAT) was measured non-intrusively to estimate each individual's blood pressure. Electrocardiogram (ECG) was measured with copper-coated electrodes and photoplethysmogram (PPG) was measured using a specially designed toilet seat apparatus. Non-intrusively measured PATs were compared with PATs measured by the standard method, and the results showed a good correlation. An equation was used to estimate blood pressure from the measured PAT during a training period for each individual. Estimated blood pressures were compared with measured blood pressures in a series of blood pressure varying experiments. For each individual, the estimated blood pressure was similar to the measured blood pressure within a tolerable error range. This method was also practiced for long-term monitoring, and the results show the value of this method for continuous home monitoring of blood pressure.

Entities:  

Mesh:

Year:  2006        PMID: 16400206     DOI: 10.1088/0967-3334/27/2/010

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

2.  Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.

Authors:  Jeong Su Lee; Jeong Heo; Won Kyu Lee; Yong Gyu Lim; Youn Ho Kim; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2014-08-12       Impact factor: 3.576

3.  Nontraditional Electrocardiogram and Algorithms for Inconspicuous In-Home Monitoring: Comparative Study.

Authors:  Nicholas J Conn; Karl Q Schwarz; David A Borkholder
Journal:  JMIR Mhealth Uhealth       Date:  2018-05-28       Impact factor: 4.773

4.  Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care.

Authors:  Ha Uk Chung; Bong Hoon Kim; Jong Yoon Lee; Jungyup Lee; Zhaoqian Xie; Erin M Ibler; KunHyuck Lee; Anthony Banks; Ji Yoon Jeong; Jongwon Kim; Christopher Ogle; Dominic Grande; Yongjoon Yu; Hokyung Jang; Pourya Assem; Dennis Ryu; Jean Won Kwak; Myeong Namkoong; Jun Bin Park; Yechan Lee; Do Hoon Kim; Arin Ryu; Jaeseok Jeong; Kevin You; Bowen Ji; Zhuangjian Liu; Qingze Huo; Xue Feng; Yujun Deng; Yeshou Xu; Kyung-In Jang; Jeonghyun Kim; Yihui Zhang; Roozbeh Ghaffari; Casey M Rand; Molly Schau; Aaron Hamvas; Debra E Weese-Mayer; Yonggang Huang; Seung Min Lee; Chi Hwan Lee; Naresh R Shanbhag; Amy S Paller; Shuai Xu; John A Rogers
Journal:  Science       Date:  2019-03-01       Impact factor: 47.728

5.  Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure.

Authors:  Syunsuke Yamanaka; Koji Morikawa; Hiroshi Morita; Ji Young Huh; Osamu Yamamura
Journal:  Front Med Technol       Date:  2021-07-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.