Echocardiographic evaluation of the Jarvik 2000 axial-flow LVAD.

Raymond F Stainback1, Mihai Croitoru, Antonieta Hernandez, Timothy J Myers, Yasmin Wadia, O H Frazier.   

Abstract

From April 2000 through September 2001, we studied 11 patients with the Jarvik 2000--a left ventricular assist device with an axial-flow pump that provides continuous blood flow--to determine the echocardiographic characteristics. All patients underwent complete echocardiographic examination, including outflow-graft flow evaluation 24 hours after implantation and each month thereafter for the duration of support. Data were obtained at each pump setting (8000-12000 rpm in 1000-rpm increments) and with the pump off. Left ventricular dimensions and shortening fraction and the duration of aortic valve systolic opening decreased as pump speed increased. Although the aortic valve remained closed at higher pump speeds, pump outflow-graft flow remained pulsatile, because of the systolic thrust of the assisted ventricle. Systolic dominance of phasic flow was more pronounced at lower pump speeds, due to normalization of the diseased heart's Starling response. When the aortic valve was closed continuously, echocardiographic contrast (indicating blood stasis) was noted in the aortic root. Because of the pump outflow graft's proximity to the chest wall, device output could be measured independently of cardiac contributions. Mean peak outflow-graft flow velocities were 0.75 +/- 0.30 m/s (systolic) and 0.41 +/- 0. 13 m/s (diastolic). When the pump was turned off briefly there was minimal regurgitation through the device into the left ventricle. This 1st echocardiographic heart function analysis of the Jarvik 2000 confirms that the device unloads the ventricle and increases cardiac output. Cardiac responses to device-speed changes can be evaluated readily with echocardiography in the early and late postoperative period.

Entities:  

Mesh:

Year:  2005        PMID: 16392203      PMCID: PMC1336693     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  3 in total

1.  Rotary pumps: new developments and future perspectives.

Authors:  Y Nosé; T Tsutsui; K C Butler; R Jarvik; Y Takami; C Nojiri; P Allaire; O Von Ramm; J Dow
Journal:  ASAIO J       Date:  1998 May-Jun       Impact factor: 2.872

2.  System considerations favoring rotary artificial hearts with blood-immersed bearings.

Authors:  R K Jarvik
Journal:  Artif Organs       Date:  1995-07       Impact factor: 3.094

3.  Five month survival in a calf supported with an intraventricular axial flow blood pump.

Authors:  S M Parnis; M P Macris; R Jarvik; J L Robinson; J W Kolff; H Anai; J M Fuqua; J L Conger; M J Cloy; T J Myers
Journal:  ASAIO J       Date:  1995 Jul-Sep       Impact factor: 2.872

  3 in total
  5 in total

Review 1.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

Review 2.  Imaging in patients after cardiac transplantation and in patients with ventricular assist devices.

Authors:  Bhanu Gupta; Dany Jacob; Randall Thompson
Journal:  J Nucl Cardiol       Date:  2015-04-02       Impact factor: 5.952

Review 3.  LVAD as a Bridge to Remission from Advanced Heart Failure: Current Data and Opportunities for Improvement.

Authors:  Christos P Kyriakopoulos; Chris J Kapelios; Elizabeth L Stauder; Iosif Taleb; Rana Hamouche; Konstantinos Sideris; Antigone G Koliopoulou; Michael J Bonios; Stavros G Drakos
Journal:  J Clin Med       Date:  2022-06-20       Impact factor: 4.964

4.  Screening for Outflow Cannula Malfunction of Left Ventricular Assist Devices (LVADs) With the Use of Doppler Echocardiography: New LVAD-Specific Reference Values for Contemporary Devices.

Authors:  Jonathan Grinstein; Eric Kruse; Keith Collins; Gabriel Sayer; Savitri Fedson; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Takeyoshi Ota; Valluvan Jeevanandam; Victor Mor-Avi; Nir Uriel; Roberto M Lang
Journal:  J Card Fail       Date:  2016-06-08       Impact factor: 5.712

5.  Echocardiographic Predictors of Hemodynamics in Patients Supported With Left Ventricular Assist Devices.

Authors:  Jonathan Grinstein; Teruhiko Imamura; Eric Kruse; Sara Kalantari; Daniel Rodgers; Sirtaz Adatya; Gabriel Sayer; Gene H Kim; Nitasha Sarswat; Jayant Raihkelkar; Takeyoshi Ota; Valluvan Jeevanandam; Daniel Burkhoff; Roberto Lang; Nir Uriel
Journal:  J Card Fail       Date:  2018-07-24       Impact factor: 5.712

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.