Literature DB >> 16389085

Numerical simulation on the biomechanical interactions of tooth/implant-supported system under various occlusal forces with rigid/non-rigid connections.

Chun-Li Lin1, Jen-Chyan Wang, Yu-Chan Kuo.   

Abstract

The aim of this study was to analyze the biomechanics in an implant/tooth-supported system under different occlusal forces with rigid/non-rigid connectors by adopting a 3D non-linear finite element (FE) approach. A 3D FE model containing one Frialit-2 implant splinted to the mandibular second premolar was constructed. Contact elements (frictional surface) were used to simulate the realistic interface condition within the implant system and the sliding keyway stress-breaker function. The stress distributions in the splinting system and dissimilar mobility between natural tooth and implant with rigid and non-rigid connectors were observed for six loading types. The simulated results indicated that the lateral occlusal forces significantly increased the implant (sigma(I, max)), alveolar bone (sigma(AB, max)) and prosthesis (sigma(P, max)) stress values when compared with the axial occlusal forces. The sigma(I, max) and sigma(AB, max) values did not exhibit significant differences regardless of the connector type used. However, the sigma(P, max) values with a non-rigid connection increased more than two times those of the rigid connection. The sigma(I, max), sigma(AB, max) and sigma(P, max) stress values were significantly reduced in centric or lateral contact situations once the occlusal forces on the pontic were decreased. Moreover, the vertical-tooth-to-implant displacement ratios with a non-rigid connection were 23 and 9.9 times that for axial and lateral loads, respectively, applied on the premolar. However, the compensated non-rigid connector capabilities were not significant when occlusal forces acted on the complete prosthesis. The non-rigid connector (keyway device) only significantly exploited its function when the occlusal forces acted on a natural tooth. Minimizing the occlusal loading force on the pontic area through occlusal adjustment procedures to redistribute stress in the maximum intercuspation or lateral working position for an implant/tooth-supported prosthesis is recommended.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16389085     DOI: 10.1016/j.jbiomech.2004.12.020

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  15 in total

1.  Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study.

Authors:  Chun-Li Lin; Yu-Hao Lin; Alvin Chao-Yu Chen
Journal:  Med Biol Eng Comput       Date:  2006-07-11       Impact factor: 2.602

2.  Mechanical interactions of cuspal-coverage designs and cement thickness in a cusp-replacing ceramic premolar restoration: a finite element study.

Authors:  Yen-Hsiang Chang; Wen-Hsueng Lin; Wen-Chieh Kuo; Chia-Yu Chang; Chun-Li Lin
Journal:  Med Biol Eng Comput       Date:  2008-08-05       Impact factor: 2.602

3.  Standard of disocclusion in complete dentures supported by implants without free distal ends: analysis by the finite elements method.

Authors:  Gustavo Diniz Greco; Estevam Barbosa de Las Casas; Tulimar P Machado Cornacchia; Cláudia Silami de Magalhães; Allyson Nogueira Moreira
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

4.  Biomechanical analysis of the stresses generated by different disocclusion patterns in an implant-supported mandibular complete denture.

Authors:  Gustavo Diniz Greco; Wellington Corrêa Jansen; Janis Landre Junior; Paulo Isaías Seraidarian
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

5.  A three-dimension finite element analysis to evaluate the stress distribution in tooth supported 5-unit intermediate abutment prosthesis with rigid and nonrigid connector.

Authors:  Ritesh Modi; Shivani Kohli; K Rajeshwari; Shekhar Bhatia
Journal:  Eur J Dent       Date:  2015 Apr-Jun

6.  Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: a three-dimensional finite element analysis.

Authors:  Pan Ma; Wei Xiong; Baosheng Tan; Wei Geng; Jiaqiang Liu; Weihong Li; Dehua Li
Journal:  Biomed Res Int       Date:  2014-07-08       Impact factor: 3.411

Review 7.  Combined Implant and Tooth Support: An Up-to-Date Comprehensive Overview.

Authors:  Mahmoud K Al-Omiri; Maher Al-Masri; Mohannad M Alhijawi; Edward Lynch
Journal:  Int J Dent       Date:  2017-03-23

8.  Tooth-implant connection with fixed partial dentures in partially edentulous arches. A retrospective cohort study over an 11.8 year observation period.

Authors:  Gregor-Georg Zafiropoulos; Moosa Abuzayeda; Adel A Al-Asfour; Syed-Saad-Bin Qasim; George Pelekos; Colin-Alexander Murray
Journal:  J Clin Exp Dent       Date:  2021-07-01

9.  Finite element reconstruction of a mandibular first molar.

Authors:  Sara Ehsani; Fatemeh Sadat Mirhashemi; Saeed Asgary
Journal:  Iran Endod J       Date:  2013-05-01

10.  An Investigation of Three types of Tooth Implant Supported Fixed Prosthesis Designs with 3D Finite Element Analysis.

Authors:  Sara Koosha; Fatemeh Sadat Mirhashemi
Journal:  J Dent (Tehran)       Date:  2013-01-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.