Usefulness of ultrasonic strain measurement-based shear modulus reconstruction for diagnosis and thermal treatment.

Chikayoshi Sumi1.   

Abstract

We previously reported an ultrasonic strain measurement-based one-dimensional (1-D) shear modulus reconstruction technique using a regularization method for differential diagnosis of malignancies on human superficial tissues (e.g., breast tissues). Here, ultrasonic strain measurement-based 2-D and 3-D shear modulus reconstruction techniques are described, and the 1-D technique is reviewed and subsequently applied to various human in vivo tissues, including deeply situated tissues (e.g., liver). Because soft tissues are deformed in 3-D space by externally situated arbitrary mechanical sources, the accuracy of the low-dimensional (i.e., 1-D or 2-D) reconstructions is lower to that of 3-D reconstruction due to occurrence of erroneous reconstruction artifacts (i.e., the reconstructed modulus is different than reality). These artifacts are confirmed on simulated inhomogeneous cubic phantoms containing a spherical homogenous inclusion using numerically calculated deformation data. The superiority of quasi-real-time imaging of the shear modulus is then demonstrated by comparing it with conventional B-mode imaging and strain imaging from the standpoints of monitoring the effectiveness of minimally invasive thermal therapy as well as differential diagnosis. Because the 2-D and 3-D techniques require special ultrasonic (US) equipment, the 1-D technique using conventional US imaging equipment is used, even though erroneous artifacts will occur. Specifically, the 1-D technique is applied as a diagnostic tool for differentiating malignancies in human in vivo liver and breast tissue, and a monitoring technique for determining the effectiveness of interstitial electromagnetic wave (micro and rf) thermal therapy on human in vivo liver and calf in vitro liver. Even when using the 1-D technique, reconstructed shear moduli were confirmed to be a suitable measure for monitoring thermal treatment as well as differential diagnosis. These results are encouraging in that they will promote use of 2-D and 3-D reconstruction techniques.

Entities:  

Mesh:

Year:  2005        PMID: 16382619     DOI: 10.1109/tuffc.2005.1561622

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  2 in total

1.  Shear modulus reconstruction by ultrasonically measured strain ratio.

Authors:  Chikayoshi Sumi; Hidenori Matsuzawa
Journal:  J Med Ultrason (2001)       Date:  2007-12-14       Impact factor: 1.314

2.  Spatially variant regularization for tissue strain measurement and shear modulus reconstruction.

Authors:  Chikayoshi Sumi
Journal:  J Med Ultrason (2001)       Date:  2007-09-14       Impact factor: 1.878

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.