Literature DB >> 16380552

Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop.

Katsuaki Yokoyama1, Hiroshi Nakagawa, Fred H M Wittkampf, Jan V Pitha, Ralph Lazzara, Warren M Jackman.   

Abstract

BACKGROUND: Electrode cooling by circulating fluid within the electrode (closed loop) or open irrigation facilitates radiofrequency (RF) ablation. This study compared lesion parameters between closed loop and open irrigation with the use of a canine model. METHODS AND
RESULTS: In 8 anesthetized dogs, the skin over the thigh muscle was incised and raised, forming a cradle superfused with heparinized blood (activated clotting time >350 seconds) at 37 degrees C. A 7F 4-mm closed loop electrode (irrigation 36 mL/min) and 7.5F 3.5-mm open irrigation electrode (irrigation 17 mL/min) were positioned perpendicular to the thigh muscle at 10 g contact weight. RF was applied (n=121) at 20 or 30 W for 60 seconds in low (0.1 m/s) or high (0.5 m/s) pulsatile blood flow. Temperatures were measured in the electrode, electrode-tissue interface, and within the tissue at 3- and 7-mm depths. After each RF, the cradle was emptied to examine the electrode and interface for thrombus. There was no difference between closed loop and open irrigation in impedance, lesion depth, or tissue temperature at 20 or 30 W. Interface temperature and electrode temperature were greater in the closed loop application. Thrombus occurred in 32 of 63 closed loop versus 0 of 58 open irrigation RF applications (P<0.05) with interface temperature > or =80 degrees C in all 32 (electrode temperature <40 degrees C in 1, 40 degrees C to 50 degrees C in 26, and >50 degrees C in 5). With closed loop, interface temperature and thrombus incidence were greater at 30 W and low blood flow. With open irrigation, interface temperature remained low (< or =71 degrees C) with no difference between 20 and 30 W or between low and high blood flow. Steam pop occurred at 20 W in 4 of 35 closed loop and 0 of 30 open irrigation and at 30 W in 15 of 28 closed loop and 4 of 28 open irrigation applications (P<0.05).
CONCLUSIONS: Lower interface temperature, thrombus, and steam pop, especially in low blood flow, indicate greater interface cooling with open irrigation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16380552     DOI: 10.1161/CIRCULATIONAHA.105.540062

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  30 in total

1.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

Review 2.  Multi-Electrode Ablation Catheters for AF Ablation: Effective Reality or Elegant Experiment?

Authors:  Lucas Boersma
Journal:  J Atr Fibrillation       Date:  2012-06-15

3.  Electrogram characteristics of the coronary sinus in cases requiring epicardial ablation within the coronary sinus for creating a conduction block at the left lateral mitral isthmus.

Authors:  Daisuke Sato; Hiroki Mani; Yu Makihara; Hiroki Kitajima; Yuji Nishikawa; Seno Keitaro; Yeong-Hwa Chun
Journal:  J Interv Card Electrophysiol       Date:  2018-06-27       Impact factor: 1.900

4.  Ablation time efficiency and lesion volume - in vitro comparison of 4 mm, non irrigated, gold- and platinum-iridium-tip radiofrequency ablation catheters.

Authors:  Tibor Balázs; Romola Laczkó; Eszter Bognár; Serkan Akman; Péter Nagy; Endre Zima; János Dobránszky; Tamás Szili-Török
Journal:  J Interv Card Electrophysiol       Date:  2012-10-26       Impact factor: 1.900

Review 5.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  J Interv Card Electrophysiol       Date:  2012-03       Impact factor: 1.900

Review 6.  [Catheter ablation of cardiac arrhythmias : Forms of energy and biophysical principles].

Authors:  Thomas Beiert; Jan W Schrickel
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2019-11-06

Review 7.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 8.  An Update on the Energy Sources and Catheter Technology for the Ablation of Atrial Fibrillation.

Authors:  Pawan K Arora; James C Hansen; Adam D Price; Josef Koblish; Boaz Avitall
Journal:  J Atr Fibrillation       Date:  2010-03-01

Review 9.  Silent Cerebral Embolism during Atrial Fibrillation Ablation:Pathophysiology, Prevention and Management.

Authors:  Matteo Anselmino; Mario Matta; Elisabetta Toso; Federico Ferraris; Davide Castagno; Marco Scaglione; Federico Cesarani; Riccardo Faletti; Fiorenzo Gaita
Journal:  J Atr Fibrillation       Date:  2013-08-31

10.  Use of a closed loop irrigated catheter in epicardial ablation of ventricular tachycardia.

Authors:  Prabhat Kumar; J Paul Mounsey; Anil K Gehi; Jennifer D Schwartz; Eugene H Chung
Journal:  J Interv Card Electrophysiol       Date:  2013-04-19       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.