Literature DB >> 16376757

Dual triggering improves the accuracy of left ventricular volume measurements by contrast-enhanced real-time 3-dimensional echocardiography.

Enrico G Caiani1, Patrick Coon, Cristiana Corsi, Sascha Goonewardena, Dianna Bardo, Patrick Rafter, Lissa Sugeng, Victor Mor-Avi, Roberto M Lang.   

Abstract

Real-time 3-dimensional echocardiographic continuous imaging (CIM) with contrast underestimates left ventricular (LV) volumes. We studied the effects of dual-triggered (DT) acquisition on the accuracy of LV volume measurements for patients with poor acoustic windows. Real-time 3-dimensional echocardiographic imaging was performed in 20 patients during LV opacification (Definity) on the same day as cardiac magnetic resonance imaging. Both CIM and DT data were analyzed using custom software to calculate end-systolic volume (ESV) and end-diastolic volume (EDV), which were compared with the cardiac magnetic resonance reference. CIM correlated well with the cardiac magnetic resonance reference (EDV: r = 0.89; ESV: r = 0.93), but underestimated EDV and ESV by 17% and 19%, respectively. In contrast, DT resulted in higher correlation (EDV: r = 0.95; ESV: r = 0.96) and smaller biases (9% and 6%, respectively). In conclusion, because the accuracy of LV volume measurements depends on the acquisition strategy of contrast-enhanced real-time 3-dimensional echocardiographic images, the use of DT instead of the conventional CIM acquisition is recommended.

Entities:  

Mesh:

Year:  2005        PMID: 16376757     DOI: 10.1016/j.echo.2005.06.008

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

Review 1.  Three-dimensional adult echocardiography: where the hidden dimension helps.

Authors:  Victor Mor-Avi; Lissa Sugeng; Roberto M Lang
Journal:  Curr Cardiol Rep       Date:  2008-05       Impact factor: 2.931

2.  MDCT coronary angiography vs 2D echocardiography for the assessment of left ventricle functional parameters.

Authors:  R Malagò; D Tavella; W Mantovani; M D'Onofrio; G Caliari; A Pezzato; L Nicolì; P Benussi; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2011-01-12       Impact factor: 3.469

Review 3.  Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis.

Authors:  Jennifer L Dorosz; Dennis C Lezotte; David A Weitzenkamp; Larry A Allen; Ernesto E Salcedo
Journal:  J Am Coll Cardiol       Date:  2012-05-15       Impact factor: 24.094

4.  Manual correction of semi-automatic three-dimensional echocardiography is needed for right ventricular assessment in adults; validation with cardiac magnetic resonance.

Authors:  Ellen Ostenfeld; Marcus Carlsson; Kambiz Shahgaldi; Anders Roijer; Johan Holm
Journal:  Cardiovasc Ultrasound       Date:  2012-01-06       Impact factor: 2.062

5.  Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Authors:  Jonas Jenner; Peder Sörensson; John Pernow; Kenneth Caidahl; Maria J Eriksson
Journal:  Clin Med Insights Cardiol       Date:  2019-03-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.