Literature DB >> 16373887

Impact of active versus usual algorithmic titration of basal insulin and point-of-care versus laboratory measurement of HbA1c on glycemic control in patients with type 2 diabetes: the Glycemic Optimization with Algorithms and Labs at Point of Care (GOAL A1C) trial.

Laurence Kennedy1, William H Herman, Poul Strange, Anthony Harris.   

Abstract

OBJECTIVE: The objective of this study was to assess the impact of active versus usual monitoring of algorithmic insulin titration and point-of-care (POC) versus laboratory HbA1c (A1C) measurement on glycemic control in primary care. RESEARCH DESIGN AND METHODS: The Glycemic Optimization with Algorithms and Labs at Point of Care (GOAL A1C) study was a 24-week, randomized, parallel-group, four-arm, open-label study of 7,893 adults with type 2 diabetes uncontrolled by oral antidiabetic agents and requiring insulin. Patients were randomly assigned by investigators from 2,164 sites in the U.S. to insulin glargine with either 1) usual (no unsolicited contact between visits) insulin titration using a simple algorithm with laboratory A1C testing, 2) usual titration with POC A1C testing, 3) active (weekly monitored) titration with laboratory A1C testing, or 4) active titration with POC A1C testing. Outcome measures included a change in A1C and fasting self-monitoring of blood glucose (SMBG) levels, percentage of patients achieving A1C <7.0%, and hypoglycemia frequency.
RESULTS: Significant A1C and SMBG reductions were observed in all arms (P < 0.0001). Compared with usual insulin titration, active titration achieved greater A1C reduction (1.5 vs. 1.3%; P < 0.0001), SMBG reduction (88 vs. 79 mg/dl; P < 0.0001), and proportion of patients achieving A1C <7.0% (38 vs. 30%; P < 0.0001). Among patients receiving active titration, POC A1C testing was associated with an increase in the proportion achieving an A1C <7.0% (41% for POC vs. 36% for laboratory; P < 0.0001). Hypoglycemia rates were low (usual vs. active groups: 3.7 vs. 6.0 all confirmed episodes/patient-year [P < 0.001]; 0.09 vs. 0.14 severe episodes/patient-year [NS]).
CONCLUSIONS: In a predominantly primary care setting, addition of insulin glargine using a simple algorithm achieved significant improvements in glycemic control in patients with type 2 diabetes in all four study arms. Active titration resulted in significant incremental improvements in glycemic control, and, among patients receiving active titration, POC A1C testing resulted in a greater portion achieving A1C <7.0%.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16373887     DOI: 10.2337/diacare.29.01.06.dc05-1058

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  38 in total

1.  Response to Swinnen et al.

Authors:  Alan C Moses; Christoph Koenen
Journal:  Diabetes Technol Ther       Date:  2010-06       Impact factor: 6.118

2.  Improving outcomes with POCT for HbA1c and blood ketone testing.

Authors:  Lori Laffel
Journal:  J Diabetes Sci Technol       Date:  2007-01

3.  Changing the glucose cut-off values that define hypoglycaemia has a major effect on reported frequencies of hypoglycaemia.

Authors:  S G H A Swinnen; P Mullins; M Miller; J B L Hoekstra; F Holleman
Journal:  Diabetologia       Date:  2008-09-20       Impact factor: 10.122

4.  Primary care diagnostic technology update: point-of-care testing for glycosylated haemoglobin.

Authors:  Annette Plüddemann; Christopher P Price; Matthew Thompson; Jane Wolstenholme; Carl Heneghan
Journal:  Br J Gen Pract       Date:  2011-02       Impact factor: 5.386

5.  Optimizing display, analysis, interpretation and utility of self-monitoring of blood glucose (SMBG) data for management of patients with diabetes.

Authors:  David Rodbard
Journal:  J Diabetes Sci Technol       Date:  2007-01

Review 6.  A review of recent literature - nurse case managers in diabetes care: equivalent or better outcomes compared to primary care providers.

Authors:  Sharon A Watts; Michelle Lucatorto
Journal:  Curr Diab Rep       Date:  2014-07       Impact factor: 4.810

Review 7.  Insulin analogs or premixed insulin analogs in combination with oral agents for treatment of type 2 diabetes.

Authors:  Philip Levy
Journal:  MedGenMed       Date:  2007-04-16

8.  The effect of early insulin therapy on pancreatic β-cell function and long-term glycemic control in newly diagnosed type 2 diabetic patients.

Authors:  Suk Chon; Seungjoon Oh; Sung Woon Kim; Jin-Woo Kim; Young Seol Kim; Jeong-taek Woo
Journal:  Korean J Intern Med       Date:  2010-08-31       Impact factor: 3.165

9.  Basal-prandial insulin delivery in type 2 diabetes mellitus via the V-Go: a novel continuous subcutaneous infusion device.

Authors:  Christoph Kapitza; Seymour Fein; Lutz Heinemann; Debra Schleusener; Steven Levesque; Poul Strange
Journal:  J Diabetes Sci Technol       Date:  2008-01

10.  Treat-to-target insulin titration algorithms when initiating long or intermediate acting insulin in type 2 diabetes.

Authors:  Poul Strange
Journal:  J Diabetes Sci Technol       Date:  2007-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.