Literature DB >> 16372278

Sensitivity-enhanced 13C MR spectroscopy of the human brain at 3 Tesla.

D W J Klomp1, W K J Renema, M van der Graaf, B E de Galan, A P M Kentgens, A Heerschap.   

Abstract

A new coil design for sensitivity-enhanced 13C MR spectroscopy (MRS) of the human brain is presented. The design includes a quadrature transmit/receive head coil optimized for 13C MR sensitivity. Loss-less blocking circuits inside the coil conductors allow this coil to be used inside a homogeneous circularly polarized 1H B1 field for 1H decoupled 13C MRS. A quadrature 1H birdcage coil optimized for minimal local RF heating makes broadband 1H decoupling in the entire human brain possible at 3 Tesla while remaining well within international safety guidelines for RF absorption. Apart from a substantial increase in sensitivity compared to conventional small linear coils, the quadrature 13C coil combined with the quadrature 1H birdcage coil allows efficient cross polarization (CP) in the brain, resulting in an additional 3.5-fold sensitivity improvement compared to direct 13C measurements without nuclear Overhauser enhancement (NOE) or polarization transfer. Combined with the gain in power efficiency, this setup allows broadband 1H to 13C CP over large areas of the brain. Clear 13C resonances from glutamate (Glu), glutamine (Gln), aspartate (Asp), lactate (Lac), and gamma-aminobutyrate (GABA) carbon spins in the human brain demonstrate the quality of 13C MR spectra obtained in vivo with this coil setup. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16372278     DOI: 10.1002/mrm.20745

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  13C MRS of occipital and frontal lobes at 3 T using a volume coil for stochastic proton decoupling.

Authors:  Shizhe Li; Yan Zhang; Shumin Wang; Maria Ferraris Araneta; Christopher S Johnson; Yun Xiang; Robert B Innis; Jun Shen
Journal:  NMR Biomed       Date:  2010-10       Impact factor: 4.044

Review 3.  13C MRS studies of neuroenergetics and neurotransmitter cycling in humans.

Authors:  Douglas L Rothman; Henk M De Feyter; Robin A de Graaf; Graeme F Mason; Kevin L Behar
Journal:  NMR Biomed       Date:  2011-08-31       Impact factor: 4.044

4.  Patients with type 1 diabetes exhibit altered cerebral metabolism during hypoglycemia.

Authors:  Kim C C van de Ven; Cees J Tack; Arend Heerschap; Marinette van der Graaf; Bastiaan E de Galan
Journal:  J Clin Invest       Date:  2013-01-09       Impact factor: 14.808

5.  Trap Design and Construction for High-Power Multinuclear Magnetic Resonance Experiments.

Authors:  Joseph V Rispoli; Ivan E Dimitrov; Sergey Cheshkov; Craig Malloy; Steven M Wright; Mary P McDougall
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-11-17       Impact factor: 1.176

6.  (13)C MRS of human brain at 7 Tesla using [2-(13)C]glucose infusion and low power broadband stochastic proton decoupling.

Authors:  Shizhe Li; Li An; Shao Yu; Maria Ferraris Araneta; Christopher S Johnson; Shumin Wang; Jun Shen
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

7.  What have novel imaging techniques revealed about metabolism in the aging brain?

Authors:  Ai-Ling Lin; Douglas L Rothman
Journal:  Future Neurol       Date:  2014-05-01

Review 8.  Dynamic imaging of brain function.

Authors:  Fahmeed Hyder
Journal:  Methods Mol Biol       Date:  2009

9.  Optimized [1-(13)C]glucose infusion protocol for 13C magnetic resonance spectroscopy at 3T of human brain glucose metabolism under euglycemic and hypoglycemic conditions.

Authors:  Kim C C van de Ven; Marinette van der Graaf; Cees J J Tack; Dennis W J Klomp; Arend Heerschap; Bastiaan E de Galan
Journal:  J Neurosci Methods       Date:  2009-11-11       Impact factor: 2.390

10.  A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Leeor Alon; Gregory Chang; Daniel K Sodickson; Ravinder R Regatte; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.