Literature DB >> 16371574

MR imaging in patients with Crohn disease: value of T2- versus T1-weighted gadolinium-enhanced MR sequences with use of an oral superparamagnetic contrast agent.

Francesca Maccioni1, Antonio Bruni, Angelo Viscido, Maria Chiara Colaiacomo, Andrea Cocco, Chiara Montesani, Renzo Caprilli, Mario Marini.   

Abstract

PURPOSE: To prospectively compare oral contrast-enhanced T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) magnetic resonance (MR) imaging with T1-weighted gadolinium-enhanced fast low-angle shot (FLASH) MR and standard examinations in the evaluation of Crohn disease.
MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Fifty-nine patients with Crohn disease underwent MR imaging after oral administration of a superparamagnetic contrast agent; RARE plain and fat-suppressed sequences and FLASH sequences were performed before and after intravenous injection of gadolinium chelate. References were endoscopic, small-bowel barium, computed tomographic, ultrasonographic, and clinical-biochemical scoring of disease activity. Two radiologists analyzed MR images for presence and extent of Crohn disease lesions, presence of strictures or other complications, and degree of local inflammation. MR findings were correlated with endoscopic, radiologic, and clinical data (kappa statistic and Spearman rank correlation test).
RESULTS: T2-weighted MR was 95% accurate, 98% sensitive, and 78% specific for detection of ileal lesions. Agreement between T1- and T2-weighted images ranged from 0.77 for ileal lesions to 1.00 for colic lesions. T2-weighted MR enabled detection of 26 of 29 severe strictures, 17 of 24 enteroenteric fistulas, and all adhesions and abscesses; T1-weighted MR enabled detection of 20 of 29 severe strictures, 16 of 24 enteroenteric fistulas, and all adhesions and abscesses. Complications leading to surgery were found in 12 (20%) patients; these were assessed correctly with either T1- or T2-weighted images. T2-weighted signal intensities of the wall and mesentery correlated with biologic activity (P < .001, r of 0.774 and 0.712, respectively). Interobserver agreement was 0.642-1.00 for T2-weighted and 0.711-1.00 for T1-weighted images.
CONCLUSION: T2-weighted MR can depict Crohn disease lesions and help assess mural and transmural inflammation with the same accuracy as gadolinium-enhanced T1-weighted MR. Combination of gadolinium-enhanced T1- and T2-weighted sequences is useful in the assessment of Crohn disease. (c) RSNA, 2005

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16371574     DOI: 10.1148/radiol.2381040244

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  50 in total

Review 1.  MRI in Crohn's disease--current and future clinical applications.

Authors:  Gionata Fiorino; Cristiana Bonifacio; Alberto Malesci; Luca Balzarini; Silvio Danese
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2011-11-22       Impact factor: 46.802

2.  Advances in the diagnosis and treatment of small bowel lesions with Crohn's disease using double-balloon endoscopy.

Authors:  Keijiro Sunada; Hironori Yamamoto; Tomonori Yano; Kentaro Sugano
Journal:  Therap Adv Gastroenterol       Date:  2009-11       Impact factor: 4.409

3.  Magnetic resonance colonography in severe attacks of ulcerative colitis.

Authors:  C Savoye-Collet; J B Roset; E Koning; C Charpentier; S Hommel; E Lerebours; J N Dacher; G Savoye
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

4.  Comparison of MR enteroclysis with MR enterography and conventional enteroclysis in patients with Crohn's disease.

Authors:  Gabriele Masselli; Emanuele Casciani; Elisabetta Polettini; Gianfranco Gualdi
Journal:  Eur Radiol       Date:  2007-09-25       Impact factor: 5.315

5.  A prospective randomized comparison between two MRI studies of the small bowel in Crohn's disease, the oral contrast method and MR enteroclysis.

Authors:  Anne Negaard; Vemund Paulsen; Leiv Sandvik; Audun Elnaes Berstad; Arne Borthne; Kirsti Try; Idar Lygren; Tryggve Storaas; Nils-Einar Klow
Journal:  Eur Radiol       Date:  2007-05-05       Impact factor: 5.315

Review 6.  [MR colography: technique, indications, and findings].

Authors:  T C Lauenstein; S Kinner; S C Ladd
Journal:  Radiologe       Date:  2008-02       Impact factor: 0.635

Review 7.  Magnetic resonance imaging for evaluation of disease activity in Crohn's disease: a systematic review.

Authors:  Karin Horsthuis; Shandra Bipat; Pieter C F Stokkers; Jaap Stoker
Journal:  Eur Radiol       Date:  2009-02-03       Impact factor: 5.315

Review 8.  Updating magnetic resonance imaging of small bowel: imaging protocols and clinical indications.

Authors:  Jiong Zhu; Jian-Rong Xu; Hong-Xia Gong; Yan Zhou
Journal:  World J Gastroenterol       Date:  2008-06-07       Impact factor: 5.742

9.  Anastomotic recurrence of Crohn's disease after ileocolic resection: comparison of MR enteroclysis with endoscopy.

Authors:  Johannes Sailer; Philipp Peloschek; Walter Reinisch; Harald Vogelsang; Karl Turetschek; Wolfgang Schima
Journal:  Eur Radiol       Date:  2008-05-27       Impact factor: 5.315

Review 10.  Surgery and diagnostic imaging in abdominal Crohn's disease.

Authors:  Fiorenzo Botti; Flavio Caprioli; Diego Pettinari; Alberto Carrara; Andrea Magarotto; Ettore Contessini Avesani
Journal:  J Ultrasound       Date:  2013-10-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.