Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed.

G Lymperopoulou1, P Papagiannis, L Sakelliou, P Karaiskos, P Sandilos, A Przykutta, D Baltas.   

Abstract

Monte Carlo simulation and experimental thermoluminescence dosimetry were utilized for the dosimetric characterization of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed. The new seed design is similar to that of the selectSeed and 6711 seeds, with the exception of its molybdenum marker. Full dosimetric data are presented following the recommendations in the Update of the AAPM Task Group 43 report (TG-43U1). A difference of 3.3% was found between Monte Carlo dose rate constant results calculated by air kerma strengths from simulations using a point detector and a detector resembling the solid angle subtended to the seed by the Wide Angle Free Air Chamber (WAFAC) in the primary standard calibration geometry. Following the TG-43U1 recommendations, an average value of lambdaMC = (0.929 +/- 0.014) cGy h(-1) U(-1) was adopted for the new seed. This value was then averaged with the measured value of lambdaEXP = (0.951 +/- 0.044) cGy h(-1) U(-1) to yield the proposed dose rate constant for the new seed that is equal to lambda = (0.940 +/- 0.051) cGy h(-1) U(-1). The Monte Carlo calculated radial dose function and two-dimensional (2-D) anisotropy function results for the new seed were found in agreement with experimental results to within statistical uncertainty of repeated measurements. Monte Carlo simulations were also performed for 125I seeds of similar geometry and dimensions for the purpose of comparison. The new seed presents dosimetric characteristics that are very similar to that of the selectSeed. In comparison to the most extensively studied Amersham 6711 seed, the new one presents similar dosimetric characteristics with a slightly reduced dose rate constant (1.5%).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16370418     DOI: 10.1118/1.2089588

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

2.  New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

Authors:  Evaggelos Pantelis; Panagiotis Papagiannis; Giorgos Anagnostopoulos; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2013-12-21

3.  Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation.

Authors:  Leonard W Zimmermann; Ahmad Amoush; Douglas A Wilkinson
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.