Literature DB >> 16363281

Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: assessment of inter- and intraobserver variation.

N Diehm1, I Baumgartner, A Silvestro, P Herrmann, J Triller, J Schmidli, D D Do, H-P Dinkel.   

Abstract

BACKGROUND: Open surgical or endovascular abdominal aortic aneurysm (AAA) relies on precise preprocedual imaging. Purpose of this study was to assess inter- and intraobserver variation of software-supported automated and manual multi row detector CT angiography (MDCTA) in aortoiliac diameter measurements before AAA repair. PATIENTS AND METHODS: Thirty original MDCTA data sets (4 x 2mm collimation) of patients scheduled for endovascular AAA repair were studied on a dedicated software capable of creating two-dimensional reformatted planes orthogonal to the aortoiliac center-line. Measurements were performed twice with afour-week interval between readings. Data were analysed by two blinded readers at random order Two different measurement methods were performed: reader-assisted freehand wall-to-wall measurement and semi-automatic measurement.
RESULTS: Aortoiliac diameters were significantly underestimated by the semi-automatic method as compared to reader-assisted measurements (p < 0.0031). Intraobserver variability of AAA diameter calculation was not significant (p > 0. 15) for reader-assisted measurements except for the diameter of the left common iliac artery in reader 2 (p = 0.0045) and it was not significant (p > 0. 14) using the semi-automatic method. Interobserver variability was not significant for AAA diameter measurements using the reader-assisted method and for proximal neck analysis with the semiautomatic method (p > 0.27). Relevant interobserver variation was observed for semi-automatic measurement of maximum AAA (p = 0.0007) and iliac artery diameters (p = 0.024).
CONCLUSIONS: Dedicated MDCTA software provides a useful tool to minimize aortoiliac diameter measurement variation and to improve imaging precision before AAA repair. For reliable AAA diameter analysis the reader-assisted freehand measurement method is recommended to be applied to a set of reformatted CT data as provided by the software used in this study.

Entities:  

Mesh:

Year:  2005        PMID: 16363281     DOI: 10.1024/0301-1526.34.4.255

Source DB:  PubMed          Journal:  Vasa        ISSN: 0301-1526            Impact factor:   1.961


  2 in total

1.  Sizing for endovascular aneurysm repair: clinical evaluation of a new automated three-dimensional software.

Authors:  Adrien Kaladji; Antoine Lucas; Gaëlle Kervio; Pascal Haigron; Alain Cardon
Journal:  Ann Vasc Surg       Date:  2010-10       Impact factor: 1.466

2.  Evaluation of computer-assisted quantification of carotid artery stenosis.

Authors:  Christina Biermann; Ilias Tsiflikas; Christoph Thomas; Bernadette Kasperek; Martin Heuschmid; Claus D Claussen
Journal:  J Digit Imaging       Date:  2012-04       Impact factor: 4.056

  2 in total