Literature DB >> 16360855

Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement.

Timothy A Turvey1, R Bryan Bell, Ceib Phillips, William R Proffit.   

Abstract

PURPOSE: This report compares the skeletal stability and treatment outcomes of 2 similar cohorts undergoing bilateral sagittal osteotomies of the mandible for advancement. The study groups included patients stabilized with 2-mm self-reinforced polylactate (PLLDL 70/30), biodegradable screws (group B), and 2-mm titanium screws placed in a positional fashion (group T).
MATERIALS AND METHODS: Sixty-nine patients underwent bilateral sagittal osteotomies of the mandibular ramus for advancement utilizing an identical technique. There were 34 patients in group B and 35 patients in group T. Each patient had preoperative, immediate postoperative, splint out, and 1-year postoperative cephalometric radiographs available for analysis. The method of analysis and treatment outcomes parameters are identical to those previously used. Repeated measures analysis of variance was performed with means of fixation as the between-subject factor and time as the within subject factor. The level of significance was set at .01.
RESULTS: There were no clinical failures in group T and a single failure in group B. The average difference in stability between the groups is small and subtly different at the mandibular angle. The data documented similarity of the postsurgical changes in the 2 groups with the only statistically significant difference being the vertical position of the gonion (P < .001) and the mandibular plane angle (P < .01) with greater upward remodeling at gonion in group T.
CONCLUSIONS: Two-mm self-reinforced PLLDL (70/30) screws can be used as effectively as 2-mm titanium screws to stabilize the mandible after bilateral sagittal osteotomies for mandibular advancement. The difference in 1-year stability and outcome is minimal.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16360855      PMCID: PMC3558282          DOI: 10.1016/j.joms.2005.09.011

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  15 in total

1.  Stability of mandibular advancement after sagittal osteotomy with screw or wire fixation: a comparative study.

Authors:  I M Watzke; T A Turvey; C Phillips; W R Proffit
Journal:  J Oral Maxillofac Surg       Date:  1990-02       Impact factor: 1.895

Review 2.  Bioabsorbable fixation devices in Orthopaedics and Traumatology.

Authors:  P U Rokkanen
Journal:  Ann Chir Gynaecol       Date:  1998

3.  The removal of plates and screws after Le Fort I osteotomy.

Authors:  B L Schmidt; D H Perrott; D Mahan; G Kearns
Journal:  J Oral Maxillofac Surg       Date:  1998-02       Impact factor: 1.895

4.  Assessment of material- and technique-related complications following sagittal split osteotomies stabilized by biodegradable polylactide screws.

Authors:  Ilkka Kallela; Pekka Laine; Riitta Suuronen; Christian Lindqvist; Tateyuki Iizuka
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-01

5.  A 5-year in vitro and in vivo study of the biodegradation of polylactide plates.

Authors:  R Suuronen; T Pohjonen; J Hietanen; C Lindqvist
Journal:  J Oral Maxillofac Surg       Date:  1998-05       Impact factor: 1.895

6.  The use of biodegradable fixation in sagittal split and vertical subsigmoid osteotomy of the mandible: a preliminary report.

Authors:  J McManners; K F Moos; A El-Attar
Journal:  Br J Oral Maxillofac Surg       Date:  1997-12       Impact factor: 1.651

7.  Osteotomy site healing following mandibular sagittal split osteotomy and rigid fixation with polylactide biodegradable screws.

Authors:  I Kallela; P Laine; R Suuronen; P Ranta; T Iizuka; C Lindqvist
Journal:  Int J Oral Maxillofac Surg       Date:  1999-06       Impact factor: 2.789

8.  The behaviour of titanium as a biomaterial: microscopy study of plates and surrounding tissues in facial osteosynthesis.

Authors:  J Acero; J Calderon; J I Salmeron; J J Verdaguer; C Concejo; M L Somacarrera
Journal:  J Craniomaxillofac Surg       Date:  1999-04       Impact factor: 2.078

9.  Resorbable plate osteosynthesis of sagittal split osteotomies with major bone movement.

Authors:  Constantin A Landes; Susanne Kriener
Journal:  Plast Reconstr Surg       Date:  2003-05       Impact factor: 4.730

10.  Mandibular, sagittal split osteotomies fixed with biodegradable or titanium screws: a prospective, comparative study of postoperative stability.

Authors:  Carlo Ferretti; Johan P Reyneke
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2002-05
View more
  10 in total

1.  Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients.

Authors:  T A Turvey; W P Proffit; C Phillips
Journal:  Int J Oral Maxillofac Surg       Date:  2010-12-24       Impact factor: 2.789

2.  Resorbable Versus Titanium Rigid Fixation for Pediatric Mandibular Fractures: A Systematic Review, Institutional Experience and Comparative Analysis.

Authors:  Matthew E Pontell; Eva B Niklinska; Stephane A Braun; Nolan Jaeger; Kevin J Kelly; Michael S Golinko
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2021-06-21

3.  Velopharyngeal Space Assessment in Patients Undergoing Le Fort 1 Maxillary Advancement.

Authors:  Eli Saleh; Joseph Saleh; Gabriel Beauchemin; Ramy El-Jalbout; Daniel E Borsuk
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-11-30

4.  Are bioresorbable polylactate devices comparable to titanium devices for stabilizing Le Fort I advancement?

Authors:  G H Blakey; E Rossouw; T A Turvey; C Phillips; W R Proffit; R P White
Journal:  Int J Oral Maxillofac Surg       Date:  2013-11-20       Impact factor: 2.789

5.  Biomaterials for craniofacial reconstruction.

Authors:  Andreas Neumann; Kevin Kevenhoerster
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

Review 6.  Bioabsorbable osteofixation for orthognathic surgery.

Authors:  Young-Wook Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-02-19

7.  Biomechanical Loading Evaluation of Unsintered Hydroxyapatite/poly-l-lactide Plate System in Bilateral Sagittal Split Ramus Osteotomy.

Authors:  Shintaro Sukegawa; Takahiro Kanno; Yoshiki Manabe; Kenichi Matsumoto; Yuka Sukegawa-Takahashi; Masanori Masui; Yoshihiko Furuki
Journal:  Materials (Basel)       Date:  2017-07-07       Impact factor: 3.623

8.  Complications of absorbable fixation in maxillofacial surgery: a meta-analysis.

Authors:  Liya Yang; Meibang Xu; Xiaolei Jin; Jiajie Xu; Jianjian Lu; Chao Zhang; Tian Tian; Li Teng
Journal:  PLoS One       Date:  2013-06-28       Impact factor: 3.240

9.  The hierarchy of stability and predictability in orthognathic surgery with rigid fixation: an update and extension.

Authors:  William R Proffit; Timothy A Turvey; Ceib Phillips
Journal:  Head Face Med       Date:  2007-04-30       Impact factor: 2.151

Review 10.  Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta-analysis and trial sequential analysis.

Authors:  Barzi Gareb; Nico B van Bakelen; Pieter U Dijkstra; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Eur J Oral Sci       Date:  2021-06-15       Impact factor: 2.612

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.