Abstract

OBJECTIVE: The aim of this retrospective clinical study was to determine whether there are any material-related problems and increased occurrence of postoperative mandibular nerve and temporomandibular joint dysfunctions in connection with the use of biodegradable self-reinforced poly-L-lactide (SR-PLLA) screws for bone fixation after bilateral sagittal split osteotomies (BSSO). STUDY
DESIGN: Forty consecutive patients who underwent BSSO and mandibular advancement that included fragment fixation using SR-PLLA screws were monitored for an average of 2.2 years postoperatively.
RESULTS: The osteotomy sites healed uneventfully with no adverse reactions. The incidence of postoperative sensory disturbances of the inferior alveolar nerve was 27%. Symptoms of temporomandibular joint disorders (TMJD) observed preoperatively in 73% of patients were reduced to 48% after surgery.
CONCLUSION: The occurrence of postoperative sensory disturbances and TMJD symptoms in this study did not deviate strikingly from that of other studies using conventional osteosynthesis. No specific complications related to the screw material were observed.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15599342     DOI: 10.1016/j.tripleo.2004.04.017

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  3 in total

1.  Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement.

Authors:  Timothy A Turvey; R Bryan Bell; Ceib Phillips; William R Proffit
Journal:  J Oral Maxillofac Surg       Date:  2006-01       Impact factor: 1.895

Review 2.  Bioabsorbable osteofixation for orthognathic surgery.

Authors:  Young-Wook Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-02-19

3.  Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial.

Authors:  B Gareb; N B van Bakelen; G J Buijs; J Jansma; J G A M de Visscher; Th J M Hoppenreijs; J E Bergsma; B van Minnen; B Stegenga; R R M Bos
Journal:  PLoS One       Date:  2017-05-11       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.