Literature DB >> 16360082

Safety and efficacy of radiofrequency energy catheter ablation of atrial fibrillation in patients with pacemakers and implantable cardiac defibrillators.

Dhanunjaya Lakkireddy1, Dimpi Patel, Kay Ryschon, Rohit Bhateja, Mihir Bhakru, Sergio Thal, Atul Verma, Oussama Wazni, Fethi Kilicaslan, Ashok Kondur, Subramanya Prasad, Jennifer Cummings, William Belden, David Burkhardt, Walid Saliba, Robert Schweikert, Mandeep Bhargava, Mina Chung, Bruce Wilkoff, Patrick Tchou, Andrea Natale.   

Abstract

BACKGROUND: Catheter ablation has significantly transformed the clinical management of atrial fibrillation (AF). The safety and efficacy of this procedure are not well understood in patients with pacemakers and defibrillators.
OBJECTIVES: The purpose of this study was to study the impact of radiofrequency catheter ablation of AF in patients with pacemakers and implantable cardiac defibrillators.
METHODS: We studied 86 patients with pacemakers and defibrillators (group I) and a similar number of age- and gender-matched controls (group II) who underwent AF ablation between 1999 and 2004. Clinical and procedural variables were compared between the two groups. In group I, various generator and lead parameters were compared before and after the procedure. Resurgence of clinical AF after 2 months was considered recurrence.
RESULTS: Both groups were similar with regard to age, gender, body mass index, and type of AF. Group I had a higher incidence of diabetes (17% vs 6%, P = .03), coronary artery disease (25% vs 13%, P = .05), less prolonged AF (31 +/- 21 vs 45 +/- 30 months, P <.001), lower left ventricular ejection fraction (49 +/- 13% vs 52 +/- 9%, P = .03), and left ventricular end-diastolic dimensions (4.97 +/- 0.81 vs 4.72 +/- 0.67, P = .03). No changes in the sensing and pacing thresholds, impedance of atrial and ventricular leads, or defibrillator coil impedance after AF ablation were observed in group I. Atrial lead dislodgment was seen in two patients. Transient abnormal but "expected" pulse generator behavior was seen in 25% of patients without permanent malfunction. Stroke (1% vs 1%, P = 1.000), pulmonary vein stenosis (2% vs 1%, P = .77), and AF recurrence rates at 12 months were similar between groups I and II, respectively (19% vs 21%, P = .73).
CONCLUSION: AF ablation is safe and efficacious in patients with pacemakers and defibrillators.

Entities:  

Mesh:

Year:  2005        PMID: 16360082     DOI: 10.1016/j.hrthm.2005.09.010

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  8 in total

Review 1.  Atrial fibrillation: catheter ablation.

Authors:  Aman Chugh; Fred Morady
Journal:  J Interv Card Electrophysiol       Date:  2006-10-20       Impact factor: 1.900

2.  Complications of catheter ablation for ventricular tachycardia.

Authors:  Aishwarya Pastapur; Daniel McBride; Amrish Deshmukh; Stefanie Driesenga; Michael Ghannam; Frank Bogun; Jackson J Liang
Journal:  J Interv Card Electrophysiol       Date:  2022-09-02       Impact factor: 1.759

3.  Radiofrequency and Cryo-Ablation Effect on Transvenous Pacing and Defibrillatory Lead Integrity: An In Vitro Study.

Authors:  Yousef H Darrat; Anuj Agarwal; Gustavo X Morales; Joseph Thompson; Ahmed Abdel-Latif; Kelly Waespe; Luigi DI Biase; Andrea Natale; Abhijit Patwardan; Claude-Samy Elayi
Journal:  J Cardiovasc Electrophysiol       Date:  2016-06-14

4.  Effects of external electrical and magnetic fields on pacemakers and defibrillators: from engineering principles to clinical practice.

Authors:  Roy Beinart; Saman Nazarian
Journal:  Circulation       Date:  2013-12-24       Impact factor: 29.690

5.  Trends in catheter ablation for atrial fibrillation in the United States.

Authors:  Patrick P Kneeland; Margaret C Fang
Journal:  J Hosp Med       Date:  2009-09       Impact factor: 2.960

6.  Simultaneous atrioventricular node ablation and leadless pacemaker implantation.

Authors:  Jeffrey Ho; Jordan M Prutkin
Journal:  HeartRhythm Case Rep       Date:  2017-01-26

Review 7.  The Effects of Catheter Ablation on Permanent Pacemakers and Implantable Cardiac Defibrillators.

Authors:  Yousef H Darrat; Gustavo X Morales; Claude S Elayi
Journal:  J Innov Card Rhythm Manag       Date:  2017-03-15

8.  Epicardial Unipolar Lead Loss of Ventricular Capture during Radiofrequency Ablation of Atrial Fibrillation.

Authors:  Daniel J Chu; Wilson W Lam
Journal:  Case Rep Cardiol       Date:  2020-01-20
  8 in total