Literature DB >> 16357065

Dual-wavelength phosphorimetry for determination of cortical and subcortical microvascular oxygenation in rat kidney.

Tanja Johannes1, Egbert G Mik, Can Ince.   

Abstract

This study presents a dual-wavelength phosphorimeter developed to measure microvascular PO2 (microPO2) in different depths in tissue and demonstrates its use in rat kidney. The used phosphorescent dye is Oxyphor G2 with excitation bands at 440 and 632 nm. The broad spectral gap between the excitation bands combined with a relatively low light absorption of 632 nm light by tissue results in a marked difference in penetration depths of both excitation wavelengths. In rat kidney, we determine the catchments depth of the 440-nm excitation to be 700 microm, whereas the catchments depth of 632 nm is as much as 4 mm. Therefore, the measurements differentiate between cortex and outer medulla, respectively. In vitro, no difference in PO2 readings between both channels was found. On the rat kidney in vivo, the measured cortical microPO2 was on average 20 Torr higher than the medullary microPO2 over a wide PO2 range induced by variations in inspired oxygen fraction. Examples provided from endotoxemia and resuscitation show differences in responses of mean cortical and medullary PO2 readings as well as in the shape of the PO2 histograms. It can be concluded that oxygen-dependent quenching of phosphorescence of Oxyphor G2 allows quantitative measurement of microPO2 noninvasively in two different depths in vivo. Oxygen levels measured by this technique in the rat renal cortex and outer medulla are consistent with previously published values detected by Clark-type oxygen electrodes. Dual-wavelength phosphorimetry is excellently suited for monitoring microPO2 changes in two different anatomical layers under pathophysiological conditions with the characteristics of providing oxygen histograms from two depths and having a penetration depth of several millimeters.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16357065     DOI: 10.1152/japplphysiol.01315.2005

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  19 in total

1.  In vivo mitochondrial oxygen tension measured by a delayed fluorescence lifetime technique.

Authors:  Egbert G Mik; Tanja Johannes; Coert J Zuurbier; Andre Heinen; Judith H P M Houben-Weerts; Gianmarco M Balestra; Jan Stap; Johan F Beek; Can Ince
Journal:  Biophys J       Date:  2008-07-18       Impact factor: 4.033

2.  Evaluation of multi-exponential curve fitting analysis of oxygen-quenched phosphorescence decay traces for recovering microvascular oxygen tension histograms.

Authors:  Rick Bezemer; Dirk J Faber; Emre Almac; Jeroen Kalkman; Matthieu Legrand; Michal Heger; Can Ince
Journal:  Med Biol Eng Comput       Date:  2010-11-03       Impact factor: 2.602

3.  Effects of exercise training on tumor hypoxia and vascular function in the rodent preclinical orthotopic prostate cancer model.

Authors:  Danielle J McCullough; Linda M-D Nguyen; Dietmar W Siemann; Bradley J Behnke
Journal:  J Appl Physiol (1985)       Date:  2013-10-31

4.  Detailing renal hemodynamics and oxygenation in rats by a combined near-infrared spectroscopy and invasive probe approach.

Authors:  Dirk Grosenick; Kathleen Cantow; Karen Arakelyan; Heidrun Wabnitz; Bert Flemming; Angela Skalweit; Mechthild Ladwig; Rainer Macdonald; Thoralf Niendorf; Erdmann Seeliger
Journal:  Biomed Opt Express       Date:  2015-01-06       Impact factor: 3.732

5.  Modulation of aquaporin-2/vasopressin2 receptor kidney expression and tubular injury after endotoxin (lipopolysaccharide) challenge.

Authors:  Frederic Chagnon; Vishal S Vaidya; Gerard E Plante; Joseph V Bonventre; Alfred Bernard; Chantal Guindi; Olivier Lesur
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

6.  Dendritic phosphorescent probes for oxygen imaging in biological systems.

Authors:  Artem Y Lebedev; Andrei V Cheprakov; Sava Sakadzić; David A Boas; David F Wilson; Sergei A Vinogradov
Journal:  ACS Appl Mater Interfaces       Date:  2009-06       Impact factor: 9.229

7.  Energy and electron transfer in enhanced two-photon-absorbing systems with triplet cores.

Authors:  Olga S Finikova; Thomas Troxler; Alessandro Senes; William F DeGrado; Robin M Hochstrasser; Sergei A Vinogradov
Journal:  J Phys Chem A       Date:  2007-07-04       Impact factor: 2.781

Review 8.  Optical oxygen sensors for applications in microfluidic cell culture.

Authors:  Samantha M Grist; Lukas Chrostowski; Karen C Cheung
Journal:  Sensors (Basel)       Date:  2010-10-15       Impact factor: 3.576

9.  Influence of fluid resuscitation on renal microvascular PO2 in a normotensive rat model of endotoxemia.

Authors:  Tanja Johannes; Egbert G Mik; Boris Nohé; Nicolaas J H Raat; Klaus E Unertl; Can Ince
Journal:  Crit Care       Date:  2006-06-19       Impact factor: 9.097

10.  Bis maltolato oxovanadium (BMOV) and ischemia/reperfusion-induced acute kidney injury in rats.

Authors:  Emre Almac; Rick Bezemer; Asli Kandil; Ugur Aksu; Dan Mj Milstein; Jan Bakker; Cihan Demirci-Tansel; Can Ince
Journal:  Intensive Care Med Exp       Date:  2014-02-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.