Literature DB >> 16357028

Comparing the level of dexterity offered by latex and nitrile SafeSkin gloves.

Jo Sawyer1, Allan Bennett.   

Abstract

An increase in the occurrence of latex allergy has been concurrent with the increasing use of latex gloves by laboratory and healthcare workers. In recent years nitrile gloves have been used to replace latex gloves to prevent latex allergy. Nitrile gloves offer a comparable level of protection against chemical and biological agents and are more puncture resistant. However, if manual dexterity is compromised by nitrile gloves to a greater degree than latex then this may increase the risk of sharps injuries. The Purdue pegboard test, which measures both gross and fine finger dexterity, was used to test the dexterity levels of two glove types used at HPA CEPR; Kimberly-Clark SafeSkin nitrile and latex laboratory gloves. There was a statistically significant 8.6% increase in fine finger dexterity provided by latex compared with nitrile SafeSkin laboratory gloves but no difference in gross dexterity between the glove types. There was no significant relationship between glove dexterity and age or gender. The selection of glove size was influenced by the digit length of participants. Moreover, those with longer, thinner fingers appeared to have an advantage when using nitrile SafeSkin gloves. The level of dexterity provided by latex and nitrile SafeSkin gloves for tasks on a gross dexterity level are comparable and health workers will benefit from the non-allergenic properties of nitrile. For tasks requiring fine finger dexterity nitrile SafeSkin gloves may impede dexterity. Despite this, the degree of restriction appears to have a negligible impact on safety in this study when compared with the risk of latex sensitization and subsequent allergy. In addition to glove material, working practices must also take into account glove size, fit, grip and thickness, as these factors can all influence dexterity.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16357028     DOI: 10.1093/annhyg/mei066

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  6 in total

1.  Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.

Authors:  Robert N Phalen; Thi Le; Weng Kee Wong
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

2.  Cold habituation does not improve manual dexterity during rest and exercise in 5 °C.

Authors:  Matthew D Muller; Yongsuk Seo; Chul-Ho Kim; Edward J Ryan; Brandon S Pollock; Keith J Burns; Ellen L Glickman
Journal:  Int J Biometeorol       Date:  2013-02-07       Impact factor: 3.787

3.  Bench Validation of a Handcrafted Prototype Catheter for Intra-gastric Pressure Monitoring.

Authors:  Alberto Federico García; Julián Chica Yantén; Álvaro Ignacio Sánchez; Jose Luis Aldana; Jorge Humberto Mejía; Daniela Burbano; Camilo Salazar
Journal:  World J Surg       Date:  2020-06       Impact factor: 3.352

4.  Common Behaviors and Faults When Doffing Personal Protective Equipment for Patients With Serious Communicable Diseases.

Authors:  Joel M Mumma; Francis T Durso; Lisa M Casanova; Kimberly Erukunuakpor; Colleen S Kraft; Susan M Ray; Andi L Shane; Victoria L Walsh; Puja Y Shah; Craig Zimring; Jennifer DuBose; Jesse T Jacob
Journal:  Clin Infect Dis       Date:  2019-09-13       Impact factor: 9.079

5.  A hand-targeted auxiliary personal protective equipment for intervention of fomite transmission of viruses.

Authors:  Justin Kok Soon Tan; Shang Wei Song; Jialiu Zeng; Chih Hung Lo
Journal:  Bioeng Transl Med       Date:  2022-09-29

6.  Dental professionals' knowledge and behavior towards utilization of gloves: a cross-sectional survey.

Authors:  Arun Suresh Dodamani; Harish Chaitram Jadhav; Mahesh Ravindra Khairnar; Rahul Gaybaro Naik
Journal:  J Prev Med Hyg       Date:  2021-01-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.