Literature DB >> 16355377

Comparison of three cytologic preparation methods and immunocytochemistries to distinguish adenocarcinoma cells from reactive mesothelial cells in serous effusion.

Junko Ueda1, Takako Iwata, Midori Ono, Mutsuo Takahashi.   

Abstract

We assessed whether a panel of seven antibodies is useful in the differentiation of adenocarcinoma cells (ACCs) from reactive mesothelial cells (RMCs) in effusion samples and to determine optimal specimen preparation conditions for immunocytochemical analysis of effusion samples. Immunocytochemistry (ICC) was performed on three types of effusion preparations from the same effusion specimens: ethanol-fixed smears, ethanol-fixed cell-blocks, and formalin-fixed cell-blocks. Commercially available antibodies MOC-31, Ber-EP4, CA19-9, CEA, EMA, CA125, and HBME-1 were tested on RMCs from four samples of various etiology and 15 samples of adenocarcinoma from various primary sites. Ethanol-fixed smears showed strong immunoreactivity to all antibodies tested. The immunoreactivity of ethanol-fixed and formalin-fixed cell-blocks was significantly lower with all antibodies except CA19-9. Smear preparations are more sensitive than cell-blocks for immunocytochemical study. A panel of antibodies MOC-31, Ber-EP4, CA19-9, and CEA appears to be suitable to distinguish between ACCs and RMCs.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16355377     DOI: 10.1002/dc.20391

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  7 in total

Review 1.  Adenocarcinoma cells in effusion cytology as a diagnostic pitfall with potential impact on clinical management: a case report with brief review of immunomarkers.

Authors:  Sinchita Roy Chowdhuri; Patricia Fetsch; Jennifer Squires; Elise Kohn; Armando C Filie
Journal:  Diagn Cytopathol       Date:  2012-11-16       Impact factor: 1.582

2.  Diagnostic accuracy of MOC-31 for malignant effusions: a meta-analysis.

Authors:  Diandian Li; Bo Wang; Qianjing Hu; Yongchun Shen; Dan Xu; Tao Wang; Fuqiang Wen
Journal:  Tumour Biol       Date:  2014-03-08

Review 3.  Gene expression profiling of non-small cell lung cancer.

Authors:  Sunil Singhal; Daniel Miller; Suresh Ramalingam; Shi-Yong Sun
Journal:  Lung Cancer       Date:  2008-04-25       Impact factor: 5.705

4.  Utility of a limited panel of calretinin and Ber-EP4 immunocytochemistry on cytospin preparation of serous effusions: A cost-effective measure in resource-limited settings.

Authors:  Raman Arora; Shipra Agarwal; Sandeep R Mathur; Kusum Verma; Venkateswaran K Iyer; Manju Aron
Journal:  Cytojournal       Date:  2011-07-28       Impact factor: 2.091

5.  Automated ERCC1 immunochemistry on hybrid cytology/tissue microarray of malignant effusions: evaluation of antibodies 8F1 and D-10.

Authors:  Alex Soltermann; Sandra Kilgus-Hawelski; Silvia Behnke; Martina Storz; Holger Moch; Beata Bode
Journal:  J Clin Bioinforma       Date:  2011-09-30

Review 6.  [Value of Cell Block in the Diagnosis of Malignant Pleural Effusion].

Authors:  Fangyuan Cheng; Qian Wang; Diansheng Zhong
Journal:  Zhongguo Fei Ai Za Zhi       Date:  2015-10-20

7.  Diagnostic accuracy of Ber-EP4 for metastatic adenocarcinoma in serous effusions: a meta-analysis.

Authors:  Bo Wang; Diandian Li; Xuemei Ou; Qun Yi; Yulin Feng
Journal:  PLoS One       Date:  2014-09-17       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.