Literature DB >> 16354740

Workplace protection of air-fed visors used in paint spraying operations.

J Bolsover1, B Rajan-Sithamparanadarajah, N Vaughan.   

Abstract

Air-fed visors are commonly used for protection against exposure to airborne isocyanates during paint spraying. Protection levels for this class of equipment are theoretically adequate, yet isocyanate sensitization in this occupation still occurs. The work reported here set out to establish the level of respiratory protection that is achieved during real paint spraying activities when air-fed visors are used. The work also examined the effects of reduced air supply flow rates on this type of respiratory protection. The workplace study highlighted common problems that occur when attempting to measure protection factors, and process and interpret the collected data. Many of the environments included in this study did not exhibit challenge concentrations high enough to reliably measure the workplace protection factor of this class of device. When detection limits are taken into consideration, the remaining field data suggest that an assigned protection factor in the region of 40 may be appropriate. When well maintained and used in accordance with the manufacturer's instructions, air-fed visors are capable of providing a good level of respiratory protection. The protection given by air-fed visors is strongly dependent on the air flow supplied to them. Laboratory measurements demonstrate that protection falls as the air supply falls. This is a gradual process and does not suddenly occur at any particular air supply flow. Observations made during the field tests indicate that there may be other activities associated with the spraying process that need to be taken into consideration when looking for sources of respiratory sensitization.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16354740     DOI: 10.1093/annhyg/mei059

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  3 in total

1.  Criteria for the collection of useful respirator performance data in the workplace.

Authors:  Larry Janssen; Ziqing Zhuang; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

2.  Air-Fed Visors Used for Isocyanate Paint Spraying--Potential Exposure When the Visor Is Lifted.

Authors:  Mike Clayton; Nick Baxter
Journal:  Ann Occup Hyg       Date:  2015-08-24

3.  Prevention guidance for isocyanate-induced asthma using occupational surveillance data.

Authors:  Carolyn Reeb-Whitaker; Naomi J Anderson; David K Bonauto
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.