Abstract

UNLABELLED: Technological advances in instruments allow the evaluation of many lymphocyte subsets in one step. The aim of this study was to evaluate the new FACSCanto flowcytometer in routine conditions, using a 6 color combination, single platform, whole blood, lysis, no wash protocol.
METHODS: Two systems were simultaneously compared on 67 blood samples and external quality controls, using CD3,CD4, CD8, CD19, CD16/56, and CD45 in one tube TRUCOUNT beads (BD Biosciences) or two tubes (TetraChrome and Flowcount, Beckman-Coulter and DakoCytomation).
RESULTS: The day-to-day instrument detection but automatic compensations were stable. Manual compensation settings were satisfactory using available facilities. Commercial and UK NEQAS quality control results were acceptable. The intra-experiment reproducibility was good (coefficient of variation (CV)<3%) but highly operator-dependent (CD4+ T cell count CVs from 1.2 to 9.7, six operators). Storage of samples was acceptable, but storage of stained samples altered absolute count reliability. Serial dilutions show a good count accuracy. The FACScanto T subsets and B cell data were highly correlated with our reference values (r2>0.87) and absolutes values were very close (slopes>0.89). The gating strategy, fluorochrome choice, and compensation setting are discussed. A few improvements are expected (sample loader, data management, auto-gating, acquisition parameters, sample mixing, absolute values calculation, etc). In conclusions, despite its complexity, 6 color staining is a reliable, stable, and highly informative technique for lymphocyte subset monitoring but remains to be optimized. Copyright (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16353133     DOI: 10.1002/cyto.b.20072

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  3 in total

1.  Evaluation of a multicolor, single-tube technique to enumerate lymphocyte subpopulations.

Authors:  F Colombo; A Cattaneo; R Lopa; P Portararo; P Rebulla; L Porretti
Journal:  Clin Vaccine Immunol       Date:  2008-04-30

2.  Single-color multitarget flow cytometry using monoclonal antibodies labeled with different intensities of the same fluorochrome.

Authors:  Joonhong Park; Kyungja Han
Journal:  Ann Lab Med       Date:  2012-04-18       Impact factor: 3.464

3.  CD56(dim)CD16(high) and CD56(bright)CD16(-) cell percentages associated with maximum knee extensor strength and incidence of death in elderly.

Authors:  Hidenobu Senpuku; Hideo Miyazaki; Akihiro Yoshihara; Saori Yoneda; Naoki Narisawa; Taketo Kawarai; Naoki Nakagawa; Motohiko Miyachi; Akio Tada; Goichiro Yoshida; Mieko Shimada; Masaharu Ohashi; Mamoru Nishimuta; Yasuo Kimura; Yutaka Yoshitake
Journal:  Springerplus       Date:  2016-03-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.