Literature DB >> 16351135

High-temperature liquid chromatography coupled on-line to a continuous-flow biochemical screening assay with electrospray ionization mass spectrometric detection.

Arjen R de Boer1, Juan M Alcaide-Hidalgo, Johannes G Krabbe, Jeffrey Kolkman, Caspar N van Emde Boas, Wilfried M A Niessen, Henk Lingeman, Hubertus Irth.   

Abstract

The potential of high-temperature liquid chromatography (HTLC) was investigated in an on-line combination with a screening system for bioactive compounds against the enzyme cathepsin B. Samples were separated by HTLC and subsequently analyzed by an on-line continuous-flow enzymatic assay. Detection was performed by electrospray ionization mass spectrometry, revealing both the bioactivity and the molecular mass of the bioactive compounds. Compared to conventional reversed-phase liquid chromatography, the amount of methanol necessary for separation could be decreased to only 10%, which improved the compatibility of LC with a biochemical assay. Sufficient preheating of the mobile phase prior to the separation and postcolumn cooling to prevent deactivation of the enzyme, even at column temperatures as high as 208 degrees C, was achieved as indicated by the reliable peak shapes obtained. The sensitivity was comparable with previously described systems operating at ambient temperatures as similar IC50 values were obtained. Exposing the inhibitors to high temperatures did not lead to thermal decomposition. The separation of inhibitors and the subsequent biochemical assay was performed either isothermally at various temperatures or by applying various temperature gradients as well as at various flow rates. The results obtained clearly show the compatibility of HTLC with an enzymatic screening assay.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16351135     DOI: 10.1021/ac0510282

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

Review 1.  Advances in mass spectrometry-based post-column bioaffinity profiling of mixtures.

Authors:  Jeroen Kool; Martin Giera; Hubertus Irth; Wilfried M A Niessen
Journal:  Anal Bioanal Chem       Date:  2010-11-24       Impact factor: 4.142

2.  On-line electrochemistry-bioaffinity screening with parallel HR-LC-MS for the generation and characterization of modified p38α kinase inhibitors.

Authors:  David Falck; Jon S B de Vlieger; Martin Giera; Maarten Honing; Hubertus Irth; Wilfried M A Niessen; Jeroen Kool
Journal:  Anal Bioanal Chem       Date:  2012-01-08       Impact factor: 4.142

Review 3.  Development of on-line high performance liquid chromatography (HPLC)-biochemical detection methods as tools in the identification of bioactives.

Authors:  Christiaan J Malherbe; Dalene De Beer; Elizabeth Joubert
Journal:  Int J Mol Sci       Date:  2012-03-07       Impact factor: 6.208

4.  Statistical Correlations between HPLC Activity-Based Profiling Results and NMR/MS Microfraction Data to Deconvolute Bioactive Compounds in Mixtures.

Authors:  Samuel Bertrand; Antonio Azzollini; Andreas Nievergelt; Julien Boccard; Serge Rudaz; Muriel Cuendet; Jean-Luc Wolfender
Journal:  Molecules       Date:  2016-02-24       Impact factor: 4.411

5.  High-Temperature Liquid Chromatography and the Hyphenation with Mass Spectrometry Using High-Pressure Electrospray Ionization.

Authors:  Lee Chuin Chen
Journal:  Mass Spectrom (Tokyo)       Date:  2019-08-26
  5 in total