We tested documented in vitro and ex vivo advantages of novel hyaluronan based heparin bonded extracorporeal circuits in a prospective randomized study. During the period from June until September 2005, 40 patients undergoing reoperation for coronary artery bypass grafting were allocated into two equal groups (n = 20): Group 1 was treated with hyaluronan-based heparin-bonded circuits and group 2 was treated with uncoated control circuits. Complete blood count, fibrinogen, albumin, C3a, interleukin-2 levels, and thromboelastographic data were documented after induction of anesthesia (T1) and heparin administration before cardiopulmonary bypass (CPB) (T2), 15 minutes after initiation of CPB (T3), before cessation of CPB (T4), 15 minutes after reversal with protamine (T5), and the first postoperative day at 8:00 a.m. (T6). Hollow fibers were collected for consecutive biomaterial analysis by optical and scanning electron microscopy (SEM). Desorbed protein deposition on fibers was compared by spectrophotometry. Leukocyte counts were lower in T4-T6 in group 1 (p < .05). Platelet counts demonstrated significant differences at T4 and T5 in coated group (p < .05). Albumin and fibrinogen levels were better preserved in Group 1 at T4, T5 and T4, T6, consecutively (p < .05). C3a and IL-2 levels were lower at T3-T5 and T4-T5 in intervention group (p < .05). Postoperative hemorrhage was 412 +/- 50 mL in group 1 and 684 +/- 50 ml in group 2 (p < .05). Respiratory support time was shorter in group 1 versus control (p < .05). Platelet adhesion was significantly lower in intervention group. Amount of desorbed protein was 1.44 +/- 0.01 mg/dL in group 1 and 1.94 +/- 0.01 mg/dL in control (p < .05). SEM and spectrophotometry demonstrated better surface preservation in the hyaluronan coated group. Novel hyaluronan-based heparin-bonded circuits reduce platelet adhesion-aggregation and protein adsorption and provide better perioperative clinical parameters through platelet, albumin, and fibrinogen-sparing effects.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16350383      PMCID: PMC4680788     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  16 in total

Review 1.  Emerging technologies in biocompatible surface modifying additives: quest for physiologic cardiopulmonary bypass.

Authors:  Serdar Gunaydin
Journal:  Curr Med Chem Cardiovasc Hematol Agents       Date:  2004-10

2.  Blood compatible aspects of poly(2-methoxyethylacrylate) (PMEA)--relationship between protein adsorption and platelet adhesion on PMEA surface.

Authors:  M Tanaka; T Motomura; M Kawada; T Anzai; Y Kasori; T Shiroya; K Shimura; M Onishi; A Mochizuki
Journal:  Biomaterials       Date:  2000-07       Impact factor: 12.479

3.  Effects of photochemically immobilized polymer coatings on protein adsorption, cell adhesion, and the foreign body reaction to silicone rubber.

Authors:  K M DeFife; M S Shive; K M Hagen; D L Clapper; J M Anderson
Journal:  J Biomed Mater Res       Date:  1999-03-05

4.  Biocompatible surfaces prepared by immobilized heparin or hyaluronate.

Authors:  R Larsson
Journal:  Acta Otolaryngol Suppl       Date:  1987

5.  Biocompatibility of Trillium Biopassive Surface-coated oxygenator versus uncoated oxygenator during cardiopulmonary bypass.

Authors:  M H Ereth; G A Nuttall; S H Clarke; J A Dearani; B K Fiechtner; C R Rishavy; D A Buda; T A Shaw; T A Orszulak; W C Oliver
Journal:  J Cardiothorac Vasc Anesth       Date:  2001-10       Impact factor: 2.628

6.  Predicting oxygenator clinical performance from laboratory in-vitro testing.

Authors:  K E Griffith; M R Vasquez; P D Beckley; B J LaLone
Journal:  J Extra Corpor Technol       Date:  1994-09

Review 7.  Biomaterial development for cardiopulmonary bypass.

Authors:  T Gourlay
Journal:  Perfusion       Date:  2001-09       Impact factor: 1.972

8.  The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption.

Authors:  Y Niimi; F Ichinose; Y Ishiguro; K Terui; S Uezono; S Morita; S Yamane
Journal:  Anesth Analg       Date:  1999-09       Impact factor: 5.108

9.  Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)-coated extracorporeal circuits.

Authors:  Serdar Gunaydin; Bora Farsak; Mustafa Kocakulak; Tamer Sari; Cem Yorgancioglu; Yaman Zorlutuna
Journal:  Ann Thorac Surg       Date:  2002-09       Impact factor: 4.330

Review 10.  Clinical uses of hyaluronan.

Authors:  E A Balazs; J L Denlinger
Journal:  Ciba Found Symp       Date:  1989
View more
  2 in total

1.  Hyaluronan based heparin free coated open and closed extracorporeal circuits for high risk coronary revascularization.

Authors:  Serdar Gunaydin; Halil Ibrahim Ucar; Tanzer Serter; Kevin McCusker; Gokhan Ozcelik; Nevriye Salman; Ali Cem Yorgancioglu
Journal:  J Extra Corpor Technol       Date:  2010-12

2.  Cardiopulmonary Bypass, Inflammation and How to Defy it: Focus on Pharmacological Interventions.

Authors:  Ali Dabbagh; Samira Rajaei; Ayad Bahadori Monfared; Ali Asghar Keramatinia; Korosh Omidi
Journal:  Iran J Pharm Res       Date:  2012       Impact factor: 1.696

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.