Literature DB >> 16344291

Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles.

Anna Balazy1, Mika Toivola, Tiina Reponen, Albert Podgórski, Anthony Zimmer, Sergey A Grinshpun.   

Abstract

Protection of the human respiratory system from exposure to nanoparticles is becoming an emerging issue in occupational hygiene. The potential adverse health effects associated with particles of approximately 1-100 nm are probably greater than submicron or micron-sized particles. The performance of two models of N95 half-facepiece-filtering respirators against nano-sized particles was evaluated at two inhalation flow rates, 30 and 85 l min(-1), following a manikin-based protocol. The aerosol concentration was measured outside and inside the facepiece using the Wide-Range Particle Spectrometer. Sodium chloride particles, conventionally used to certify N-series respirators under NIOSH 42 CFR 84 regulations, were utilized as the challenge aerosol. The targeted particle sizes ranged from 10 to 600 nm, although the standard certification tests are performed with particles of approximately 300 nm, which is assumed to be the most penetrating size. The results indicate that the nanoparticle penetration through a face-sealed N95 respirator may be in excess of the 5% threshold, particularly at high respiratory flow rates. Thus, N95 respirators may not always provide the expected respiratory protection for workers. The highest penetration values representing the poorest respirator protection conditions were observed in the particle diameter range of approximately 30-70 nm. Based on the theoretical simulation, we have concluded that for respirators utilizing mechanical filters, the peak penetration indeed occurs at the particle diameter of approximately 300 nm; however, for pre-charged fiber filters, which are commonly used for N95 respirators, the peak shifts toward nano-sizes. This study has confirmed that the neutralization of particles is a crucial element in evaluating the efficiency of a respirator. The variability of the respirator's performance was determined for both models and both flow rates. The analysis revealed that the coefficient of variation of the penetration ranged from 0.10 to 0.54 for particles of 20-100 nm in diameter. The fraction of N95 respirators for which the performance test at 85 l min(-1) demonstrated excessive (>5%) penetration of nanoparticles was as high as 9/10. The test results obtained in a relatively small (0.096 m(3)) test chamber and in a large (24.3 m(3)) walk-in chamber were found essentially the same, thus, suggesting that laboratory-based evaluations have a good potential to adequately represent the respirator field performance.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16344291     DOI: 10.1093/annhyg/mei058

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  44 in total

1.  Assessing the potential exposure risk and control for airborne titanium dioxide and carbon black nanoparticles in the workplace.

Authors:  Min-Pei Ling; Chia-Pin Chio; Wei-Chun Chou; Wei-Yu Chen; Nan-Hung Hsieh; Yi-Jun Lin; Chung-Min Liao
Journal:  Environ Sci Pollut Res Int       Date:  2011-01-28       Impact factor: 4.223

2.  Evaluating the efficacy of cloth facemasks in reducing particulate matter exposure.

Authors:  Kabindra M Shakya; Alyssa Noyes; Randa Kallin; Richard E Peltier
Journal:  J Expo Sci Environ Epidemiol       Date:  2016-08-17       Impact factor: 5.563

3.  Particle Count Statistics Applied to the Penetration of a Filter Challenged with Nanoparticles.

Authors:  Patrick T O'Shaughnessy; Linda H Schmoll
Journal:  Aerosol Sci Technol       Date:  2013-01-01       Impact factor: 2.908

4.  Performance of two respiratory protective devices used by home-attending health care workers (a pilot study).

Authors:  Reported By Yousef Elmashae; Sergey A Grinshpun; Tiina Reponen; Michael Yermakov; Robert Riddle
Journal:  J Occup Environ Hyg       Date:  2017-09       Impact factor: 2.155

5.  Absence of keratins 8 and 18 in rodent epithelial cell lines associates with keratin gene mutation and DNA methylation: Cell line selective effects on cell invasion.

Authors:  Raymond Kwan; Kok Sun Looi; M Bishr Omary
Journal:  Exp Cell Res       Date:  2015-04-14       Impact factor: 3.905

6.  Mathematical modeling of the effectiveness of facemasks in reducing the spread of novel influenza A (H1N1).

Authors:  Samantha M Tracht; Sara Y Del Valle; James M Hyman
Journal:  PLoS One       Date:  2010-02-10       Impact factor: 3.240

7.  Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

Authors:  Xinjian He; Sergey A Grinshpun; Tiina Reponen; Roy McKay; Michael S Bergman; Ziqing Zhuang
Journal:  Ann Occup Hyg       Date:  2013-10-08

8.  What does respirator certification tell us about filtration of ultrafine particles?

Authors:  Robert M Eninger; Takeshi Honda; Tiina Reponen; Roy McKay; Sergey A Grinshpun
Journal:  J Occup Environ Hyg       Date:  2008-05       Impact factor: 2.155

9.  Air sampling filtration media: Collection efficiency for respirable size-selective sampling.

Authors:  Jhy-Charm Soo; Keenan Monaghan; Taekhee Lee; Mike Kashon; Martin Harper
Journal:  Aerosol Sci Technol       Date:  2015-12-14       Impact factor: 2.908

10.  Engineered nanomaterials: exposures, hazards, and risk prevention.

Authors:  Robert A Yokel; Robert C Macphail
Journal:  J Occup Med Toxicol       Date:  2011-03-21       Impact factor: 2.646

View more