Literature DB >> 16338137

A biomechanical comparison of the Mitek RapidLoc, Mitek Meniscal repair system, clearfix screws and vertical PDS and Ti-Cron sutures.

S Z H Naqui1, W A Thiryayi, P Hopgood, W G Ryan.   

Abstract

The aim of this in vitro study was to measure and compare the biomechanical properties and mode of failure of the five different methods of meniscal repair. Reproducible tears were created in 50 bovine medial menisci and repaired in a standardized fashion with one of the following devices: the RapidLoc meniscal repair device (Mitek Products, Westwood, MA), an 8 mm Mitek meniscal repair system (Mitek Products, Westwood, MA), Clearfix screw (Innovasive Devices, Marlborough, MA), a single vertical mattress suture of 2-0 Ti-Cron (Ethicon, Massachusetts) and a vertical mattress suture of No. 1 PDS II (Johnson and Johnson Int.). The repairs were tested by single cycle load to failure in a materials testing machine. The mean loads to failure for each of the repair groups were as follows: Mitek RapidLoc 44.9 N, Mitek meniscal repair system 20.3 N, Clearfix screw 37.4 N, vertical Ti-Cron 66.1 N and vertical PDS suture 103.0 N. The mean load to failure was significantly greater with PDS vertical sutures than with other techniques (P<0.05). The Mitek RapidLoc had the least extension at failure (14.8 mm) (P<0.05). This study confirms meniscal repair with vertical PDS sutures confers the highest biomechanical stability and that the new Mitek RapidLoc device offers improved load to failure than the previous generations.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16338137     DOI: 10.1016/j.knee.2005.09.004

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  6 in total

1.  Biomechanical evaluation of arthroscopic all-inside meniscus repairs.

Authors:  Taner Gunes; Bora Bostan; Mehmet Erdem; Murat Asci; Cengiz Sen; Mehmet Halidun Kelestemur
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

2.  Long-term outcome after all-inside meniscal repair using the RapidLoc system.

Authors:  Eirik Solheim; Janne Hegna; Eivind Inderhaug
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-14       Impact factor: 4.342

3.  The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus.

Authors:  Ashraf Abdelkafy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-12       Impact factor: 4.342

4.  The effect of inclination angle on the strength of vertical mattress configuration for meniscus repair.

Authors:  Mehmet Erduran; Onur Hapa; Baran Şen; Yavuz Kocabey; Diler Erdemli; Mehran Aksel; Hasan Havitçioğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-09       Impact factor: 4.342

5.  What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Authors:  Francois Hardeman; Kristoff Corten; Michiel Mylle; Bert Van Herck; René Verdonk; Peter Verdonk; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-12       Impact factor: 4.342

6.  Continuous Meniscal Suture Technique of the Knee.

Authors:  José Leonardo Rocha de Faria; Douglas Mello Pavão; Alfredo Marques Villardi; Eduardo Branco de Sousa; João Matheus Guimarães; José Maurício de Morais Carmo; Alan de Paula Mozella
Journal:  Arthrosc Tech       Date:  2020-05-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.