Literature DB >> 1633451

Physics and dosimetry of the gamma knife.

A Wu1.   

Abstract

Since 1968, the gamma knife has been one of the major radiosurgical devices. Although approximately 4300 patients worldwide had been treated with the gamma knife units through June 1990, gamma knife installments in the United States are still rather scarce compared to linear accelerators adapted for radiosurgery. This article describes the basic physical characteristics of the gamma knife, patient set-up procedures, the existing treatment-planning system, the measurements of dosimetry and physical parameters, dose delivery accuracy, and quality assurance procedures. It also includes a vision of future developments and improvements in these areas.

Entities:  

Mesh:

Year:  1992        PMID: 1633451

Source DB:  PubMed          Journal:  Neurosurg Clin N Am        ISSN: 1042-3680            Impact factor:   2.509


  10 in total

1.  Ocular arterial blood flow of choroidal melanoma eyes before and after stereotactic radiotherapy using Leksell gamma knife: 2 year follow up.

Authors:  P V Vécsei; K Kircher; G Nagel; S Toma-Bstaendig; I Ruhswurm; M Georgopoulos; M Zehetmayer
Journal:  Br J Ophthalmol       Date:  1999-12       Impact factor: 4.638

Review 2.  Mouse models for radiation-induced cancers.

Authors:  Leena Rivina; Michael J Davoren; Robert H Schiestl
Journal:  Mutagenesis       Date:  2016-05-21       Impact factor: 3.000

3.  Spatial shifts in frame-based Gamma Knife radiosurgery: A case for cone beam CT imaging as quality assurance using the Gamma Knife® Icon™.

Authors:  M Sean Peach; Daniel M Trifiletti; Sunil W Dutta; James M Larner; David J Schlesinger; Jason P Sheehan
Journal:  J Radiosurg SBRT       Date:  2018

4.  Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery.

Authors:  Jessica Molinier; Christine Kerr; Sebastien Simeon; Norbert Ailleres; Marie Charissoux; David Azria; Pascal Fenoglietto
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

5.  Quality assurance of beam accuracy for Leksell Gamma Unit.

Authors:  C Yu; Z Petrovich; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

6.  Ion chamber measurements of transverse gamma knife beam profiles.

Authors:  Morris I Bank
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

7.  Gamma Knife radiosurgery for vestibular schwannomas: Evaluation of planning using the sphericity degree of the target volume.

Authors:  Crystian Wilian Chagas Saraiva; Simone Coutinho Cardoso; Daniela Piai Groppo; Antônio Afonso Ferreira De Salles; Luiz Fernando de Ávila; Luiz Antonio Ribeiro da Rosa
Journal:  PLoS One       Date:  2020-01-10       Impact factor: 3.240

8.  Reproducibility and geometric accuracy of the Fixster system during hypofractionated stereotactic radiotherapy.

Authors:  Peter Lindvall; Per Bergström; Per-Olov Löfroth; Roger Henriksson; A Tommy Bergenheim
Journal:  Radiat Oncol       Date:  2008-05-28       Impact factor: 3.481

9.  Linac-based stereotactic radiosurgery for treatment of trigeminal neuralgia.

Authors:  Bruce J Gerbi; Patrick D Higgins; Kwan H Cho; Walter A Hall
Journal:  J Appl Clin Med Phys       Date:  2004-07-01       Impact factor: 2.102

10.  Inter- and intrafractional dose uncertainty in hypofractionated Gamma Knife radiosurgery.

Authors:  Taeho Kim; Jason Sheehan; David Schlesinger
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.