Literature DB >> 16333163

Clinical application of the OneDose Patient Dosimetry System for total body irradiation.

S Best1, A Ralston, N Suchowerska.   

Abstract

The OneDose Patient Dosimetry System (Sicel Technologies) is a new dosimeter based on metal oxide semiconductor field-effect transistor technology and designed for the in vivo measurement of patient dose during radiotherapy. In vivo dosimetry for total body irradiation (TBI) is challenging due to the extended treatment distance, low dose rates and beam spoilers. Phantom results confirm the suitability of the dosimeter for TBI in terms of inherent build-up, post-irradiation fading, accuracy, reproducibility, linearity and temperature dependence. Directional dependence is significant and should be taken into account. The OneDose dosimeters were also trialed in vivo for two TBI patients and the dose measured compared to conventional dosimeter measurements using an ionization chamber and thermoluminescent dosimeters (TLD), with agreement to within 2.2% and 3.9%, respectively. Phantom and patient results confirm that the OneDose patient dosimetry system is a practical and convenient alternative to TLDs for TBI in vivo dosimetry. For increased confidence in results with this dosimeter, we recommend that two dosimeters be used for each site of interest.

Entities:  

Mesh:

Year:  2005        PMID: 16333163     DOI: 10.1088/0031-9155/50/24/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Multistage evaluation and commissioning of a pre-calibrated, single-use OneDosePlus MOSFET system for in vivo dosimetry in a radiotherapy department.

Authors:  A P M Lonsdale
Journal:  Br J Radiol       Date:  2011-11-01       Impact factor: 3.039

2.  Is the in vivo dosimetry with the OneDosePlusTM system able to detect intra-fraction motion? A retrospective analysis of in vivo data from breast and prostate patients.

Authors:  Maria Daniela Falco; Marco D'Andrea; Alessia Lo Bosco; Mauro Rebuzzi; Elisabetta Ponti; Barbara Tolu; Grazia Tortorelli; Rosaria Barbarino; Luana Di Murro; Riccardo Santoni
Journal:  Radiat Oncol       Date:  2012-06-20       Impact factor: 3.481

3.  Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

Authors:  Essam H Mattar; Lina F Hammad; Huda I Al-Mohammed
Journal:  Med Sci Monit       Date:  2011-07

4.  Evaluation of clinical use of OneDose metal oxide semiconductor field-effect transistor detectors compared to thermoluminescent dosimeters to measure skin dose for adult patients with acute lymphoblastic leukemia.

Authors:  Huda Ibrahim Al-Mohammed
Journal:  N Am J Med Sci       Date:  2011-08

5.  Patient dosimetry for total body irradiation using single-use MOSFET detectors.

Authors:  Tina Marie Briere; Ramesh Tailor; Naresh Tolani; Karl Prado; Richard Lane; Shiao Woo; Chul Ha; Michael T Gillin; A Sam Beddar
Journal:  J Appl Clin Med Phys       Date:  2008-11-03       Impact factor: 2.102