Literature DB >> 16331036

Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery.

Arthur C K Cheng1, Dorothy Fan, Emily Tang, Dennis S C Lam.   

Abstract

PURPOSE: To evaluate the effect of corneal curvature and corneal thickness on the assessment of intraocular pressure (IOP) using noncontact tonometry (NCT) in patients after myopic LASIK surgery.
METHODS: All patients who had myopic LASIK in a university-based eye clinic between February 2002 and May 2002 were retrospectively analyzed. Preoperative NCT was compared with postoperative NCT, postoperative corneal thickness, and postoperative corneal curvature.
RESULTS: The difference between the mean preoperative NCT (15.46 +/- 2.50 mm Hg) and postoperative NCT (6.30 +/- 1.57 mm Hg) was significant (9.16 +/- 1.96 mm Hg, P < 0.010). Preoperative NCT significantly correlated with postoperative NCT (P < 0.001), postoperative corneal thickness (P = 0.006), and postoperative anterior corneal curvature (P < 0.010).
CONCLUSIONS: Both corneal thickness and anterior corneal curvature affect IOP assessment in patients with myopic LASIK. Although correction formulas can be used to estimate the actual IOP, alternative methods should be investigated to assess IOP independent of corneal thickness and curvature.

Entities:  

Mesh:

Year:  2006        PMID: 16331036     DOI: 10.1097/01.ico.0000164833.69668.02

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  7 in total

1.  Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery.

Authors:  Antonios P Aristeidou; Georgios Labiris; Andreas Katsanos; Michalis Fanariotis; Nikitas C Foudoulakis; Vassilios P Kozobolis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-06-25       Impact factor: 3.117

2.  Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

Authors:  Shirin Hamed-Azzam; Daniel Briscoe; Oren Tomkins; Raneen Shehedeh-Mashor; Hanna Garzozi
Journal:  Int Ophthalmol       Date:  2012-12-29       Impact factor: 2.031

3.  A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an "intraocular pressure constant".

Authors:  Ayse Ebru Bahadir Kilavuzoglu; Tahir Kansu Bozkurt; Cemile Banu Cosar; Asım Bozkurt Sener
Journal:  Int Ophthalmol       Date:  2017-06-24       Impact factor: 2.031

4.  Changes in Schlemm's canal, trabecular meshwork, and relevant parameters in the early stage after SMILE of myopia patients.

Authors:  Dan-Dan Yang; Zhi-Qi Chen; Wei Chen; He Yin; Jing-Kai Peng; Jun-Ming Wang
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

5.  Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE).

Authors:  Yang Shen; Xiangjian Su; Xiu Liu; Huamao Miao; Xuejun Fang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-11-18       Impact factor: 2.209

6.  Intraocular Pressure and Its Relation to Ocular Geometry: Results From the Gutenberg Health Study.

Authors:  Esther M Hoffmann; Fidan Aghayeva; Felix M Wagner; Achim Fiess; Markus Nagler; Thomas Münzel; Philipp S Wild; Manfred E Beutel; Irene Schmidtmann; Karl J Lackner; Norbert Pfeiffer; Alexander K Schuster
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-01-03       Impact factor: 4.799

7.  Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction.

Authors:  Mohamed Hosny; Fayrouz Aboalazayem; Hoda El Shiwy; Mohsen Salem
Journal:  Clin Ophthalmol       Date:  2017-07-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.