Literature DB >> 16328310

Periodontal anaesthesia reduces common 8 Hz input to masseters during isometric biting.

Paul F Sowman1, Russell S A Brinkworth, Kemal S Türker.   

Abstract

During isometric contractions of the jaw muscles, oscillations in the rectified masseteric EMG record that are coherent with the mandibular force output are evident at ~8 Hz. We have investigated the load dependence of these oscillations under both force and EMG feedback conditions and the extent to which these oscillations are coupled bilaterally in the jaw muscles. We further investigated the extent to which afferent information arising from the periodontium during biting influenced the extent of ~8 Hz EMG tremor and the bilateral coupling between masseters at this frequency. Using coherence analysis we have shown that a significant load-independent coupling of EMG between the closing muscles of the jaw occurs at ~8 Hz as a result of common ~8 Hz input to the masseters. This common input is significantly reduced when afferent information from the periodontium is blocked. These results suggest that afferent information arising from the periodontium enhances the expression of peripheral tremulous activity, which may be important for optimising the response of the jaw to changes in forces occurring between the teeth.

Entities:  

Mesh:

Year:  2005        PMID: 16328310     DOI: 10.1007/s00221-005-0144-5

Source DB:  PubMed          Journal:  Exp Brain Res        ISSN: 0014-4819            Impact factor:   1.972


  64 in total

1.  Pulsatile central nervous control of human movement.

Authors:  S F Farmer
Journal:  J Physiol       Date:  1999-05-15       Impact factor: 5.182

2.  Rectification and non-linear pre-processing of EMG signals for cortico-muscular analysis.

Authors:  L J Myers; M Lowery; M O'Malley; C L Vaughan; C Heneghan; A St Clair Gibson; Y X R Harley; R Sreenivasan
Journal:  J Neurosci Methods       Date:  2003-04-15       Impact factor: 2.390

3.  Coupling of oscillatory activity between muscles is strikingly reduced in a deafferented subject compared with normal controls.

Authors:  J M Kilner; R J Fisher; R N Lemon
Journal:  J Neurophysiol       Date:  2004-04-07       Impact factor: 2.714

4.  Tremor and other oscillations in neuromuscular systems.

Authors:  R B Stein; M N Oğuztöreli
Journal:  Biol Cybern       Date:  1976       Impact factor: 2.086

5.  Human cortical 40 Hz rhythm is closely related to EMG rhythmicity.

Authors:  S Salenius; R Salmelin; C Neuper; G Pfurtscheller; R Hari
Journal:  Neurosci Lett       Date:  1996-08-02       Impact factor: 3.046

6.  An extended difference of coherence test for comparing and combining several independent coherence estimates: theory and application to the study of motor units and physiological tremor.

Authors:  A M Amjad; D M Halliday; J R Rosenberg; B A Conway
Journal:  J Neurosci Methods       Date:  1997-04-25       Impact factor: 2.390

7.  Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor.

Authors:  R J Elble; J E Randall
Journal:  J Neurophysiol       Date:  1976-03       Impact factor: 2.714

8.  Demodulation of e.m.g.s of pathological tremours. Development and testing of a demodulator for clinical use.

Authors:  H L Journée; J van Manen; J J van der Meer
Journal:  Med Biol Eng Comput       Date:  1983-03       Impact factor: 2.602

9.  Comparison of electromyogram spectra with force spectra during human elbow tremor.

Authors:  P B Matthews; R B Muir
Journal:  J Physiol       Date:  1980-05       Impact factor: 5.182

10.  Resetting of tremor by mechanical perturbations: a comparison of essential tremor and parkinsonian tremor.

Authors:  R G Lee; R B Stein
Journal:  Ann Neurol       Date:  1981-12       Impact factor: 10.422

View more
  6 in total

1.  Mandibular physiological tremor is reduced by increasing-force ramp contractions and periodontal anaesthesia.

Authors:  Paul F Sowman; Russell S A Brinkworth; Kemal S Türker
Journal:  Exp Brain Res       Date:  2007-08-08       Impact factor: 1.972

2.  Multi-muscle control during bipedal stance: an EMG-EMG analysis approach.

Authors:  Alessander Danna-Dos-Santos; Tjeerd W Boonstra; Adriana M Degani; Vinicius S Cardoso; Alessandra T Magalhaes; Luis Mochizuki; Charles T Leonard
Journal:  Exp Brain Res       Date:  2013-10-09       Impact factor: 1.972

3.  Is the human masticatory system devoid of recurrent inhibition?

Authors:  K S Türker; A Schmied; A Rossi; R Mazzocchio; P F Sowman; J P Vedel
Journal:  Exp Brain Res       Date:  2006-11-30       Impact factor: 1.972

4.  Mouse incising central pattern generator: Characteristics and modulation by pain.

Authors:  Charles G Widmer; Joyce Morris-Wiman
Journal:  Physiol Behav       Date:  2018-08-25

5.  Periodontal anaesthetisation decreases rhythmic synchrony between masseteric motor units at the frequency of jaw tremor.

Authors:  Paul F Sowman; Kirstin M Ogston; Kemal S Türker
Journal:  Exp Brain Res       Date:  2007-01-10       Impact factor: 2.064

6.  The Dynamics of Voluntary Force Production in Afferented Muscle Influence Involuntary Tremor.

Authors:  Christopher M Laine; Akira Nagamori; Francisco J Valero-Cuevas
Journal:  Front Comput Neurosci       Date:  2016-08-19       Impact factor: 2.380

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.