Literature DB >> 16322728

Coupling pediatric ventricle assist devices to the Fontan circulation: simulations with a lumped-parameter model.

Kerem Pekkan1, David Frakes, Diane De Zelicourt, Carol W Lucas, W James Parks, Ajit P Yoganathan.   

Abstract

In pediatric ventricular assist device (VAD) design, the process of matching device characteristics and dimensions to the relevant disease conditions poses a formidable challenge because the disease spectrum is more highly varied than for adult applications. One example arises with single-ventricle congenital defects, which demand palliative surgeries that create elevated systemic venous pressure and altered pulmonary hemodynamics. Substituting a mechanical pump as a right ventricle has long been proposed to eliminate the associated early and postoperative anomalies. A pulsatile lumped-parameter model of the single-ventricle circulation was developed to guide the preliminary design studies. Two special modules, the pump characteristics and the total cavopulmonary connection (TCPC) module, are introduced. The TCPC module incorporates the results of three-dimensional patient-specific computational fluid dynamics calculations, where the pressure drop in the TCPC anastomosis is calculated at the equal vascular lung resistance operating point for different cardiac outputs at a steady 60/40 inferior vena cava/superior vena cava flow split. Preliminary results obtained with the adult parameters are presented with no ventricle remodeling or combined larger-size single ventricle. A detailed literature review of single-ventricle function is provided. Coupling a continuous pump to the single-ventricle circulation brought both the pulmonary and systemic venous pressures back to manageable levels. Selected VADs provided an acceptable cardiac output trace of the single left ventricle, after initial transients. Remodeling of the systemic venous compliance plays a critical role in performance and is included in this study. Pulsatile operation mode with rotational speed regulation highlighted the importance of TCPC and pulmonary artery compliances. Four different pumps and three patient-specific anatomical TCPC pathologies were studied. Magnitudes of the equivalent TCPC resistances were found to be comparable to the vascular resistances of the normal baseline circulation, significantly affecting both the VAD design and hemodynamics.

Entities:  

Mesh:

Year:  2005        PMID: 16322728     DOI: 10.1097/01.mat.0000176169.73987.0d

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  20 in total

1.  The use of a numerical model to simulate the cavo-pulmonary assistance in Fontan circulation: a preliminary verification.

Authors:  Arianna Di Molfetta; Antonio Amodeo; Libera Fresiello; Sergio Filippelli; Mara Pilati; Roberta Iacobelli; Rachele Adorisio; Dionisio Colella; Gianfranco Ferrari
Journal:  J Artif Organs       Date:  2015-11-06       Impact factor: 1.731

2.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

3.  Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model.

Authors:  Bryan C Good; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2015-07-10       Impact factor: 3.934

4.  Imaging and patient-specific simulations for the Fontan surgery: current methodologies and clinical applications.

Authors:  Diane A de Zélicourt; Alison Marsden; Mark A Fogel; Ajit P Yoganathan
Journal:  Prog Pediatr Cardiol       Date:  2010-12-01

5.  Exercise capacity in the Bidirectional Glenn physiology: Coupling cardiac index, ventricular function and oxygen extraction ratio.

Authors:  Carolina Vallecilla; Reza H Khiabani; Phillip Trusty; Néstor Sandoval; Mark Fogel; Juan Carlos Briceño; Ajit P Yoganathan
Journal:  J Biomech       Date:  2015-04-06       Impact factor: 2.712

6.  Hemodynamic performance of stage-2 univentricular reconstruction: Glenn vs. hemi-Fontan templates.

Authors:  Kerem Pekkan; Lakshimi P Dasi; Diane de Zélicourt; Kartik S Sundareswaran; Mark A Fogel; Kirk R Kanter; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2008-11-06       Impact factor: 3.934

7.  Patient-specific surgical planning and hemodynamic computational fluid dynamics optimization through free-form haptic anatomy editing tool (SURGEM).

Authors:  Kerem Pekkan; Brian Whited; Kirk Kanter; Shiva Sharma; Diane de Zelicourt; Kartik Sundareswaran; David Frakes; Jarek Rossignac; Ajit P Yoganathan
Journal:  Med Biol Eng Comput       Date:  2008-08-05       Impact factor: 2.602

8.  Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation.

Authors:  David C Wendell; Margaret M Samyn; Joseph R Cava; Laura M Ellwein; Mary M Krolikowski; Kimberly L Gandy; Andrew N Pelech; Shawn C Shadden; John F LaDisa
Journal:  Med Eng Phys       Date:  2012-08-20       Impact factor: 2.242

Review 9.  Modeling the Fontan circulation: where we are and where we need to go.

Authors:  C G DeGroff
Journal:  Pediatr Cardiol       Date:  2007-10-05       Impact factor: 1.655

10.  Computational modeling for bedside application.

Authors:  Roy C P Kerckhoffs; Sanjiv M Narayan; Jeffrey H Omens; Lawrence J Mulligan; Andrew D McCulloch
Journal:  Heart Fail Clin       Date:  2008-07       Impact factor: 3.179

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.