Literature DB >> 16319520

Comparison of radiosurgery planning modalities for acoustic neuroma with regard to conformity and mean target dose.

J R Perks1, K El-Hamri, T P D Blackburn, P N Plowman.   

Abstract

PURPOSE: To evaluate dose conformity and mean target dose in light of previous comparative studies and state-of-the-art radiosurgery delivery modalities.
MATERIALS AND METHODS: Seven patients with acoustic neuromas deemed clinically suitable for linear accelerator or Gamma Knife radiosurgery were planned such that the minimum doses for any plan were equal. Gamma Knife plans were prepared in three ways: by altering the prescription of previously published data, by hand and with the assistance of an automatic planning algorithm (wizard). The linear accelerator plans were prepared utilizing a micro-multileaf collimator in both static and dynamic modes. The dose volume histogram analyses lead to a measure of conformity and the mean and minimum target dose for each plan. Statistical significance was calculated as each planning modality was compared with every other.
RESULTS: All Gamma Knife plans demonstrated a statistically significantly better conformity when compared with fixed field linear accelerator techniques. When compared to linear accelerator techniques the wizard-assisted Gamma Knife plans demonstrated significantly better conformity. The mean target dose for all the Gamma Knife plans was significantly higher than that of the linear accelerator plans (19.2 Gy vs. 13.4 Gy).
CONCLUSIONS: Conformity of the prescription isodose to the target shape is of major importance in radiosurgery. The modalities compared represent commercially available and widely accepted systems. Gamma Knife plans derived using the 'wizard' option and finalized by hand yield the best conformity. Copyright 2005 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2005        PMID: 16319520     DOI: 10.1159/000089987

Source DB:  PubMed          Journal:  Stereotact Funct Neurosurg        ISSN: 1011-6125            Impact factor:   1.875


  2 in total

1.  Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions.

Authors:  Q Jackie Wu; Zhiheng Wang; John P Kirkpatrick; Zheng Chang; Jeffrey J Meyer; Mei Lu; Calvin Huntzinger; Fang-Fang Yin
Journal:  Radiat Oncol       Date:  2009-01-21       Impact factor: 3.481

2.  IntuitivePlan inverse planning performance evaluation for Gamma Knife radiosurgery of AVMs.

Authors:  Ian Paddick; Diana Grishchuk; Alexis Dimitriadis
Journal:  J Appl Clin Med Phys       Date:  2020-08-04       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.