Literature DB >> 16319085

Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data.

Lawrence D Jacobs1, Ivan S Salgo, Sascha Goonewardena, Lynn Weinert, Patrick Coon, Dianna Bardo, Olivier Gerard, Pascal Allain, Jose L Zamorano, Leopoldo P de Isla, Victor Mor-Avi, Roberto M Lang.   

Abstract

AIMS: Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. METHODS AND
RESULTS: CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland-Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (-14 mL, -6.5 mL, -1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (-23 mL, -15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%).
CONCLUSION: Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.

Entities:  

Mesh:

Year:  2005        PMID: 16319085     DOI: 10.1093/eurheartj/ehi666

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  65 in total

Review 1.  Early detection of chemotherapy-related left ventricular dysfunction.

Authors:  Jeanne M DeCara
Journal:  Curr Cardiol Rep       Date:  2012-06       Impact factor: 2.931

Review 2.  Echocardiographic assessment of left ventricular systolic function: from ejection fraction to torsion.

Authors:  Matteo Cameli; Sergio Mondillo; Marco Solari; Francesca Maria Righini; Valentina Andrei; Carla Contaldi; Eugenia De Marco; Michele Di Mauro; Roberta Esposito; Sabina Gallina; Roberta Montisci; Andrea Rossi; Maurizio Galderisi; Stefano Nistri; Eustachio Agricola; Donato Mele
Journal:  Heart Fail Rev       Date:  2016-01       Impact factor: 4.214

3.  Noninvasive modalities for the assessment of left ventricular function: all are equal but some are more equal than others.

Authors:  Tiong Keng Lim; Roxy Senior
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

4.  Real-time three-dimensional echocardiographic assessment of left ventricular remodeling index in patients with hypertensive heart disease and coronary artery disease.

Authors:  Ming Chen; Jing Wang; Mingxing Xie; Xinfang Wang; Qing Lv; Lei Wang; Yan Li; Manli Fu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2009-02-18

Review 5.  Added value of real-time three-dimensional echocardiography in assessing cardiac masses.

Authors:  Juan Carlos Plana
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

Review 6.  Quantitative assessment of left ventricular systolic function using 3-dimensional echocardiography.

Authors:  Rahul Mehrotra; R Alagesan; Sameer Srivastava
Journal:  Indian Heart J       Date:  2013-09-23

Review 7.  Three-dimensional adult echocardiography: where the hidden dimension helps.

Authors:  Victor Mor-Avi; Lissa Sugeng; Roberto M Lang
Journal:  Curr Cardiol Rep       Date:  2008-05       Impact factor: 2.931

8.  Acute volume loading exacerbates direct ventricular interaction in a model of COPD.

Authors:  William S Cheyne; Alexandra M Williams; Megan I Harper; Neil D Eves
Journal:  J Appl Physiol (1985)       Date:  2017-07-20

Review 9.  Three-dimensional echocardiography. New possibilities in mitral valve assessment.

Authors:  Jorge Solis; Marta Sitges; Robert A Levine; Judy Hung
Journal:  Rev Esp Cardiol       Date:  2009-02       Impact factor: 4.753

10.  Assessing the Cardiac Toxicity of Chemotherapeutic Agents: Role of Echocardiography.

Authors:  Timothy C Tan; Marielle Scherrer-Crosbie
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.