Literature DB >> 16318963

Mirena at caesarean section.

M Puzey1.   

Abstract

The aim of the study was to audit the clinical experience of insertion of the Mirena intrauterine system at the time of a caesarean section. The Mirena apparatus was inserted into the fundus of the uterus after delivery of the foetus and placenta. Thirty-three patients were analysed in private practice over 32 woman-years. The audit revealed the device was extremely well tolerated. There were no contraceptive failures, no complications and no expulsions of the intrauterine device. Patient satisfaction was extremely high. At the conclusion of the audit, only one device had been removed; this descriptive study showed that the Mirena intrauterine device can be inserted into the uterus at caesarean section to provide an immediate, reliable and reversible contraceptive.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16318963     DOI: 10.1080/13625180500233851

Source DB:  PubMed          Journal:  Eur J Contracept Reprod Health Care        ISSN: 1362-5187            Impact factor:   1.848


  5 in total

1.  Expulsion of intrauterine devices after postpartum placement by timing of placement, delivery type, and intrauterine device type: a systematic review and meta-analysis.

Authors:  Sarah H Averbach; Yokabed Ermias; Gary Jeng; Kathryn M Curtis; Maura K Whiteman; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Naomi K Tepper; Tara C Jatlaoui
Journal:  Am J Obstet Gynecol       Date:  2020-03-03       Impact factor: 8.661

2.  Intrauterine Device Expulsion After Postpartum Placement: A Systematic Review and Meta-analysis.

Authors:  Tara C Jatlaoui; Maura K Whiteman; Gary Jeng; Naomi K Tepper; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Kathryn M Curtis
Journal:  Obstet Gynecol       Date:  2018-10       Impact factor: 7.661

3.  A randomised clinical trial to assess satisfaction with the levonorgestrel- releasing intrauterine system inserted at caesarean section compared to postpartum placement.

Authors:  Kathleen Braniff; Edmund Gomez; Reinhold Muller
Journal:  Aust N Z J Obstet Gynaecol       Date:  2015-06-05       Impact factor: 2.100

Review 4.  Insertion of intrauterine devices after cesarean section: a systematic review update.

Authors:  Norman D Goldstuck; Petrus S Steyn
Journal:  Int J Womens Health       Date:  2017-04-18

Review 5.  Intrauterine contraception after cesarean section and during lactation: a systematic review.

Authors:  Norman D Goldstuck; Petrus S Steyn
Journal:  Int J Womens Health       Date:  2013-12-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.