Literature DB >> 16315059

Traumatic complications from placement of thoracic catheters and tubes.

Freddie R Swain1, Felipe Martinez, Mark Gripp, Rahul Razdan, Joseph Gagliardi.   

Abstract

The volume of critically ill patients requiring stabilization in emergency departments (EDs) throughout the USA has increased from 42 million per year in 1960 to over 92 million in 1990, as reported by Goldstein [Crit Care Clinics 21(1):81-89, 2005] and Rivers et al. [Curr Opin Crit Care 8(6):600-606, 2002]. With the increase in this patient population, the number of procedures, both invasive and noninvasive, performed in the ED to improve clinical outcomes has also increased. Therefore, emergency medicine physicians must add to their repertoire the ability to recognize potentially fatal traumatic complications. This review will provide readers with imaging findings of traumatic complications from placement of thoracic catheters and tubes and briefly discuss pitfalls of performing these procedures. In particular, complications arising from placement of hemodialysis catheters, central venous catheters, Swan-Ganz catheters, chest tubes, nasogastric and feeding tubes, and endotracheal tubes will be reviewed.

Entities:  

Mesh:

Year:  2005        PMID: 16315059     DOI: 10.1007/s10140-005-0447-7

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  35 in total

1.  Contralateral reexpansion pulmonary edema.

Authors:  B J Heller; M K Grathwohl
Journal:  South Med J       Date:  2000-08       Impact factor: 0.954

2.  Morbidity of percutaneous tube thoracostomy in trauma patients.

Authors:  M Deneuville
Journal:  Eur J Cardiothorac Surg       Date:  2002-11       Impact factor: 4.191

3.  Superiority of the internal jugular over the subclavian access for temporary dialysis.

Authors:  G E Cimochowski; E Worley; W E Rutherford; J Sartain; J Blondin; H Harter
Journal:  Nephron       Date:  1990       Impact factor: 2.847

4.  Routine chest radiographs after central line insertion: mandatory postprocedural evaluation or unnecessary waste of resources?

Authors:  B Lucey; J C Varghese; P Haslam; M J Lee
Journal:  Cardiovasc Intervent Radiol       Date:  1999 Sep-Oct       Impact factor: 2.740

5.  Complications of tube thoracostomy for acute trauma.

Authors:  J S Millikan; E E Moore; E Steiner; G E Aragon; C W Van Way
Journal:  Am J Surg       Date:  1980-12       Impact factor: 2.565

6.  Tunneled infusion catheters: increased incidence of symptomatic venous thrombosis after subclavian versus internal jugular venous access.

Authors:  S O Trerotola; J Kuhn-Fulton; M S Johnson; H Shah; W T Ambrosius; P H Kneebone
Journal:  Radiology       Date:  2000-10       Impact factor: 11.105

Review 7.  CT diagnosis of malpositioned chest tubes.

Authors:  G Gayer; J Rozenman; C Hoffmann; S Apter; D A Simansky; A Yellin; Y Itzchak
Journal:  Br J Radiol       Date:  2000-07       Impact factor: 3.039

8.  Pulmonary artery rupture associated with the Swan-Ganz catheter.

Authors:  T J Kearney; M M Shabot
Journal:  Chest       Date:  1995-11       Impact factor: 9.410

9.  Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance.

Authors:  E Gualtieri; S A Deppe; M E Sipperly; D R Thompson
Journal:  Crit Care Med       Date:  1995-04       Impact factor: 7.598

10.  Fatal outcome of jugular vein cannulation.

Authors:  R W Stewart; M Hardjasudarma; L Nall; G Mathews; R Davis
Journal:  South Med J       Date:  1995-11       Impact factor: 0.954

View more
  2 in total

Review 1.  To breathe or not to breathe: a review of artificial airway placement and related complications.

Authors:  John Donatelli; Ayushi Gupta; Ramya Santhosh; Todd R Hazelton; Leelakrishna Nallamshetty; Alvaro Macias; Carlos A Rojas
Journal:  Emerg Radiol       Date:  2014-09-30

2.  Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique.

Authors:  Matheus M Mantovani; Denise T Fantoni; André M Gimenes; Jacqueline R de Castro; Patrícia B Flor; Keila K Ida; Denise S Schwartz
Journal:  BMC Vet Res       Date:  2017-11-09       Impact factor: 2.741

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.