Literature DB >> 16312013

A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry.

Claire Turner1, Patrik Spanel, David Smith.   

Abstract

Selected-ion flow-tube mass spectrometry (SIFT-MS) has been used to monitor the volatile compounds in the exhaled breath of 30 volunteers (19 male, 11 female) over a 6-month period. Volunteers provided breath samples each week between 8:45 and 13:00 (before lunch), and the concentrations of several trace compounds were obtained. In this paper the focus is on ethanol and acetaldehyde, which were simultaneously quantified by SIFT-MS using H3O+ precursor ions. The mean ethanol level for all samples was 196 parts-per-billion (ppb) with a standard deviation of 244 ppb, and the range of values for breath samples analysed is 0 to 1663 ppb. The mean acetaldehyde level for all samples was 24 ppb with a standard deviation of 17 ppb, and the range of values for breath samples analysed is 0 to 104 ppb. Background (ambient air) levels of ethanol were around 50 ppb, whereas any background acetaldehyde was usually undetectable. Increased ethanol levels were observed if sweet drink/food had been consumed within the 2 h prior to providing the breath samples, but no increase was apparent when alcohol had been consumed the previous evening. The measured endogenous breath ethanol and acetaldehyde levels were not correlated. These data relating to healthy individuals are a prelude to using breath analysis for clinical diagnosis, for example, the recognition of bacterial overload in the gut (ethanol) or the possibly of detecting tumours in the body (acetaldehyde). (c) 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16312013     DOI: 10.1002/rcm.2275

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  18 in total

1.  Membrane inlet mass spectrometry for homeland security and forensic applications.

Authors:  Stamatios Giannoukos; Boris Brkić; Stephen Taylor; Neil France
Journal:  J Am Soc Mass Spectrom       Date:  2014-11-15       Impact factor: 3.109

2.  Loss of adaptive capacity in asthmatic patients revealed by biomarker fluctuation dynamics after rhinovirus challenge.

Authors:  Anirban Sinha; René Lutter; Binbin Xu; Tamara Dekker; Barbara Dierdorp; Peter J Sterk; Urs Frey; Edgar Delgado Eckert
Journal:  Elife       Date:  2019-11-05       Impact factor: 8.140

3.  Product ion distributions for the reactions of NO+ with some physiologically significant aldehydes obtained using a SRI-TOF-MS instrument.

Authors:  Paweł Mochalski; Karl Unterkofler; Patrik Španěl; David Smith; Anton Amann
Journal:  Int J Mass Spectrom       Date:  2014-04-15       Impact factor: 1.986

4.  Halitosis: a new definition and classification.

Authors:  M Aydin; C N Harvey-Woodworth
Journal:  Br Dent J       Date:  2014-07-11       Impact factor: 1.626

5.  Portable Electronic Nose for Analyzing the Smell of Nasal Secretions in Calves: Toward Noninvasive Diagnosis of Infectious Bronchopneumonia.

Authors:  Tatiana Kuchmenko; Anastasiia Shuba; Ruslan Umarkhanov; Anton Chernitskiy
Journal:  Vet Sci       Date:  2021-04-27

6.  Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits.

Authors:  Chuji Wang; Peeyush Sahay
Journal:  Sensors (Basel)       Date:  2009-10-19       Impact factor: 3.576

7.  Standardised exhaled breath collection for the measurement of exhaled volatile organic compounds by proton transfer reaction mass spectrometry.

Authors:  Andras Bikov; Koralia Paschalaki; Ron Logan-Sinclair; Ildiko Horváth; Sergei A Kharitonov; Peter J Barnes; Omar S Usmani; Paolo Paredi
Journal:  BMC Pulm Med       Date:  2013-07-09       Impact factor: 3.317

8.  Breath acetone monitoring by portable Si:WO3 gas sensors.

Authors:  Marco Righettoni; Antonio Tricoli; Samuel Gass; Alex Schmid; Anton Amann; Sotiris E Pratsinis
Journal:  Anal Chim Acta       Date:  2012-06-12       Impact factor: 6.558

9.  Human breath analysis may support the existence of individual metabolic phenotypes.

Authors:  Pablo Martinez-Lozano Sinues; Malcolm Kohler; Renato Zenobi
Journal:  PLoS One       Date:  2013-04-03       Impact factor: 3.240

10.  Gas signatures from Escherichia coli and Escherichia coli-inoculated human whole blood.

Authors:  Brandon J Umber; Hye-Won Shin; Simone Meinardi; Szu-Yun Leu; Frank Zaldivar; Dan M Cooper; Donald R Blake
Journal:  Clin Transl Med       Date:  2013-07-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.