Clinical comparison of tympanic membrane displacement with invasive intracranial pressure measurements.

S Shimbles1, C Dodd, K Banister, A D Mendelow, I R Chambers.   

Abstract

A non-invasive method of assessing intracranial pressure (ICP) would be of benefit to patients with abnormal cerebral pathology that could give rise to changes in ICP. In particular, it would assist the regular monitoring of hydrocephalus patients. This study evaluated a technique using tympanic membrane displacement (TMD) measurements, which has been reported to provide a reliable, non-invasive measure of ICP. A group of 135 hydrocephalus patients was studied, as well as 13 patients with benign intracranial hypertension and a control group of 77 volunteers. TMD measurements were carried out using the Marchbanks measurement system analyser and compared between the groups. In 36 patients, invasive measurements of ICP carried out at the same time were compared with the TMD values. A highly significant relationship was found between TMD and ICP but intersubject variability was high and the predictive value of the technique low. Taking the normal range of ICP to be 10-15 mmHg, the predictive limits of the regression are an order of magnitude wider than this and therefore Vm cannot be used as a surrogate for ICP. In conclusion, TMD measurements do not provide a reliable non-invasive measure of ICP in patients with shunted hydrocephalus.

Entities:  

Mesh:

Year:  2005        PMID: 16311455     DOI: 10.1088/0967-3334/26/6/017

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  17 in total

1.  Could intracranial pressure in traumatic brain injury be measured or predicted noninvasively? Almost.

Authors:  Nino Stocchetti
Journal:  Intensive Care Med       Date:  2007-08-01       Impact factor: 17.440

Review 2.  Non-invasive intracranial pressure assessment.

Authors:  Llewellyn C Padayachy
Journal:  Childs Nerv Syst       Date:  2016-07-21       Impact factor: 1.475

3.  Non-invasive assessment of ICP in children: advances in ultrasound-based techniques.

Authors:  Llewellyn C Padayachy; C Robba; R Brekken
Journal:  Childs Nerv Syst       Date:  2019-10-04       Impact factor: 1.475

4.  Posture systematically alters ear-canal reflectance and DPOAE properties.

Authors:  Susan E Voss; Modupe F Adegoke; Nicholas J Horton; Kevin N Sheth; Jonathan Rosand; Christopher A Shera
Journal:  Hear Res       Date:  2010-03-19       Impact factor: 3.208

5.  Can intracranial pressure be measured non-invasively bedside using a two-depth Doppler-technique?

Authors:  Lars-Owe D Koskinen; Jan Malm; Rolandas Zakelis; Laimonas Bartusis; Arminas Ragauskas; Anders Eklund
Journal:  J Clin Monit Comput       Date:  2016-03-14       Impact factor: 2.502

6.  Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods-A Review.

Authors:  P H Raboel; J Bartek; M Andresen; B M Bellander; B Romner
Journal:  Crit Care Res Pract       Date:  2012-06-08

Review 7.  Advances in neuro-monitoring.

Authors:  Charu Mahajan; Girija Prasad Rath; Parmod Kumar Bithal
Journal:  Anesth Essays Res       Date:  2013 Sep-Dec

8.  Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods.

Authors:  Danilo Cardim; Chiara Robba; Joseph Donnelly; Michal Bohdanowicz; Bernhard Schmidt; Maxwell Damian; Georgios V Varsos; Xiuyun Liu; Manuel Cabeleira; Gustavo Frigieri; Brenno Cabella; Peter Smielewski; Sergio Mascarenhas; Marek Czosnyka
Journal:  J Neurotrauma       Date:  2015-12-17       Impact factor: 5.269

9.  The tympanic membrane displacement analyser for monitoring intracranial pressure in children.

Authors:  Samson Gwer; Victoria Sheward; Anthony Birch; Robert Marchbanks; Richard Idro; Charles R Newton; Fenella J Kirkham; Jean-Pierre Lin; Ming Lim
Journal:  Childs Nerv Syst       Date:  2013-01-30       Impact factor: 1.475

10.  Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.

Authors:  Dachuan Liu; Zhen Li; Xuxiang Zhang; Liping Zhao; Jianping Jia; Fei Sun; Yaxing Wang; Daqing Ma; Wenbin Wei
Journal:  BMC Neurol       Date:  2017-09-29       Impact factor: 2.474