Literature DB >> 16309999

Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up.

Kin-Wing Cheung1, Shu-Hang Yung, Kwok-Chuen Wong, Kwok-Hing Chiu.   

Abstract

The early results of smooth hydroxyapatite-coated press-fit acetabular cup are comparable to porous-coated press-fit cup, but these results deteriorate dramatically after 5 years. In this study, 66 primary total hip arthroplasties performed between 1994 and 1998 were reviewed. The average follow-up was 6.5 years. Of the 66 arthroplasties, 8 acetabular cups were revised for aseptic loosening presenting as rapid change of cup position. The average duration of symptoms before revision was 3 months. The survival of the cups at 5 and 9 years were 95.4% and 83%, respectively. The rapid clinical deterioration after 5 years may be due to lack of bone ingrowth into the cup making it unable to resist the shearing stress in the acetabulum. Radiolucent line was not an accurate sign for the detection of mechanical failure.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16309999     DOI: 10.1016/j.arth.2004.10.002

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

2.  Effects of hydroxyapatite coating of cups used in hip revision arthroplasty.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2012-09-03       Impact factor: 3.717

3.  Effects of hydroxyapatite coating on survival of an uncemented femoral stem. A Swedish Hip Arthroplasty Register study on 4,772 hips.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2011-07-13       Impact factor: 3.717

4.  The Current Concepts of Total Hip Arthroplasty.

Authors:  Joong-Myung Lee
Journal:  Hip Pelvis       Date:  2016-12-28

5.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

6.  Early catastrophic failure of Birmingham acetabular dysplasia cup in revision arthroplasty: a case report.

Authors:  Manjunath Ramappa; Andrew Port
Journal:  Cases J       Date:  2009-07-30
  6 in total