Literature DB >> 16309424

Prevalence of Legionella pneumophila serogroup 1 in water distribution systems in Izmir province of Turkey.

Ataç Uzel1, Füsun Uçar, E Esin Hameş-Kocabaş.   

Abstract

Legionella pneumophila serogroup 1 occurrence has been investigated in 168 hot water samples from 24 hotels, situated in 6 counties in Izmir province of Turkey, from 15 June to 30 September of the year 2000. Sampling was carried out at 15-day intervals and seven samples were taken from each of the hotels' hot water reservoirs and hot water networks. The samples were (1 L) concentrated using polycarbonate filters (mesh size 0.22 microm). Isolation was achieved using selective medium, GVPC agar. The samples were concentrated by membrane filtration, divided into three portions and cultured without pretreatment, after acid treatment, and after heat treatment, on GVPC agar. One hundred and ten isolates were identified as L.pneumophila sg 1 using the Legionella Latex Test (Oxoid). Arbitrarily primed PCR (AP PCR) was employed to assess the clonal relationship between Legionella pneumophila sg 1 isolates from the hot water samples of the hotels. Three genotypes of L. pneumophila sg 1 isolates were identified. With a high prevalence of type A, 22 hotels were found to be colonized with L. pneumophila serogroup 1, while only 2 were free from the bacteria.

Entities:  

Mesh:

Year:  2005        PMID: 16309424     DOI: 10.1111/j.1600-0463.2005.apm_118.x

Source DB:  PubMed          Journal:  APMIS        ISSN: 0903-4641            Impact factor:   3.205


  5 in total

1.  Acanthamoeba keratitis due to Acanthamoeba genotype T4 in a non-contact-lens wearer in Turkey.

Authors:  Hatice Ertabaklar; Meral Türk; Volkan Dayanir; Sema Ertuğ; Julia Walochnik
Journal:  Parasitol Res       Date:  2006-09-30       Impact factor: 2.289

2.  Environmental surveillance of Legionella in tourist facilities of the Balearic Islands, Spain, 2006 to 2010 and 2015 to 2018.

Authors:  Antonio Doménech-Sánchez; Elena Laso; Clara I Berrocal; Sebastián Albertí
Journal:  Euro Surveill       Date:  2022-05

3.  Legionella Colonization of Hotel Water Systems in Touristic Places of Greece: Association with System Characteristics and Physicochemical Parameters.

Authors:  Maria A Kyritsi; Varvara A Mouchtouri; Antonis Katsioulis; Elina Kostara; Vasileios Nakoulas; Marina Hatzinikou; Christos Hadjichristodoulou
Journal:  Int J Environ Res Public Health       Date:  2018-11-30       Impact factor: 3.390

4.  Design, Development, and Performance Evaluation of Solar Heating System for Disinfection of Domestic Roof-Harvested Rainwater.

Authors:  O A Akintola; A Y Sangodoyin
Journal:  Int Sch Res Notices       Date:  2015-01-12

5.  Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey.

Authors:  Michele Totaro; Paola Valentini; Anna Laura Costa; Lorenzo Frendo; Alessia Cappello; Beatrice Casini; Mario Miccoli; Gaetano Privitera; Angelo Baggiani
Journal:  Int J Environ Res Public Health       Date:  2017-10-26       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.