Literature DB >> 16308897

Accuracy of fetal lung volume assessed by three-dimensional sonography.

R Ruano1, J Martinovic, M Dommergues, M-C Aubry, Y Dumez, A Benachi.   

Abstract

OBJECTIVE: To determine the accuracy and precision of prenatal three-dimensional (3D) ultrasound in estimating fetal lung volume using the rotational multiplanar technique (VOCAL) by comparing it to postmortem volume measurements.
METHODS: Fetal lung volume was measured during 3D ultrasound examination using a rotational multiplanar technique in eight cases of congenital diaphragmatic hernia (CDH) (six left and two right-sided) and in 25 controls without pulmonary malformation, immediately before termination. Prenatal 3D sonographic estimates of fetal lung volume were compared with postmortem measurement of fetal lung volume achieved by water displacement.
RESULTS: The intraclass correlation coefficient of fetal lung volume estimated by 3D ultrasound and measured at postmortem examination was 0.95 in CDH cases and 0.99 in controls. Based on Bland-Altman analysis, the bias, precision and limits of agreement were, respectively, 0.35 cm(3), 1.46 cm(3) and between -2.51 and + 3.21 cm(3) in cases with CDH and 0.08 cm(3), 2.80 cm(3) and between -5.41 and + 5.57 cm(3) in controls. The mean relative error of 3D ultrasound fetal lung volume measurement was -7.19% (from -42.70% to + 18.11%) in CDH cases and -0.72% (from -30.25% to + 19.22%) in controls, while the mean absolute error of 3D ultrasound fetal lung volume measurement was 1.40 (range, 0.71-2.52) cm(3) and 2.12 (range, 0.05-4.98) cm(3), respectively. Accuracy of 3D ultrasound for measuring fetal lung volumes was 84.86 (range, 57.30-99.48)% in cases with CDH and 91.38 (range, 69.75-99.45)% in controls. The mean intraobserver variability for lung volume estimated by 3D ultrasound was 0.28 cm(3) in controls and 0.17 cm(3) in CDH cases.
CONCLUSION: Prenatal 3D ultrasound can estimate accurately fetal lung volume using the rotational multiplanar technique for volume measurements (VOCAL), even in fetuses with very small lungs, such as cases with isolated CDH.

Entities:  

Mesh:

Year:  2005        PMID: 16308897     DOI: 10.1002/uog.2624

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

1.  Multi-modality Echocardiography for Cardiac Assessment in Fetuses of Pregnant Women With Diabetes Mellitus.

Authors:  Hee Joung Choi
Journal:  J Cardiovasc Imaging       Date:  2022-04

2.  The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders.

Authors:  S-C Chiou; M-H Hsieh; H-Y Chen; J-D Lin; C-C Chen; W-H Hsu; L-B Jeng; C-T Chang; R-H Chen; T-Y Wang; W-L Haung
Journal:  J Endocrinol Invest       Date:  2009-02       Impact factor: 4.256

3.  Reference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography.

Authors:  Luciano Marcondes Machado Nardozza; Ana Paula Passos; Edward Araujo Júnior; Rafael Frederico Bruns; Antonio Fernandes Moron
Journal:  Radiol Bras       Date:  2014 Jul-Aug

4.  Reference range of fetal thorax using two-dimensional and three-dimensional ultrasound VOCAL technique and application in fetal thoracic malformations.

Authors:  Xihua Lian; Zhenhong Xu; Liping Zheng; Zhixing Zhu; Tofunmi Ejiwale; Ayush Kumar; Peiya Cai; Shaozheng He; Shunlan Liu; Ying Zhang; Guorong Lyu
Journal:  BMC Med Imaging       Date:  2021-02-22       Impact factor: 1.930

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.