Literature DB >> 16306724

Optimal puncture site of the right internal jugular vein after laryngeal mask airway placement.

Kazuhide Takeyama1, Hiroyuki Kobayashi, Toshiyasu Suzuki.   

Abstract

BACKGROUND: Puncturing of the internal jugular vein (IJV) after placement of a laryngeal mask airway (LMA) is difficult. Overlapping of the right internal jugular vein (IJV) and common carotid artery (CCA) after placement of an LMA-Classic (Laryngeal Mask Company, Henley-on-Thames, United Kingdom) was investigated using an ultrasound scanner. A study was conducted to determine the optimal puncture site in the case of puncturing the right IJV after LMA-Classic placement.
METHODS: The subjects in this study consisted of 114 patients (60 men and 54 women) scheduled to undergo LMA-Classic placement (size 4 for men and size 3 for women). Overlapping between the IJV and CCA was investigated at three points (high, middle, and low points) on the right side of the neck after LMA-Classic placement. A test puncture was also made at the right low (supraclavicular) point after LMA-Classic placement.
RESULTS: (1) The degree of overlapping of the right IJV and CCA after LMA-Classic placement was clearly greater than before LMA placement. (2) With the exception of some measurements, there were many cases in which the right IJV and CCA were completely overlapping after LMA-Classic placement. Furthermore, the CCA was not observed in the vicinity of the right IJV at the right low point. (3) There were no complications (including pneumothorax and accidental arterial puncture) during supraclavicular IJV puncture after LMA-Classic placement.
CONCLUSION: After placement of the LMA-Classic, overlapping of the IJV and CCA increased at the high and middle puncture points of the IJV; however, at the lower puncture point, the position of the vessels remained unaffected. Therefore, during IJV puncture at high or middle points, ultrasound guidance is advisable to avoid CCA puncture.

Entities:  

Mesh:

Year:  2005        PMID: 16306724     DOI: 10.1097/00000542-200512000-00006

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  7 in total

1.  Optimal head rotation and puncture site for internal jugular vein cannulation after laryngeal mask airway insertion.

Authors:  Won Ho Kim; Mi Sook Gwak; Soo Joo Choi; Sang Hoon Song; Myung Hee Kim
Journal:  Singapore Med J       Date:  2015-08       Impact factor: 1.858

2.  [Ultrasound-guided central venous access in adults and children: Procedure and pathological findings].

Authors:  P Scheiermann; F H Seeger; R Breitkreutz
Journal:  Anaesthesist       Date:  2010-01       Impact factor: 1.041

3.  Effect of laryngeal mask airway placement on the optimal site and success rate of venipuncture via the right internal jugular vein.

Authors:  Huan-Qiu Liu; Xin-Bai Li; Yu-Shuang Zhang; Ji Li
Journal:  Int J Clin Exp Med       Date:  2015-08-15

4.  An ultrasound study of cerebral venous drainage after internal jugular vein catheterization.

Authors:  Davide Vailati; Massimo Lamperti; Matteo Subert; Alberto Sommariva
Journal:  Crit Care Res Pract       Date:  2012-05-17

5.  Ultrasonographic assessment of altered anatomical relationship between internal jugular vein and common carotid artery with supraglottic airway in children: LMA vs i-gel™.

Authors:  Rakhi Khemka; Sonal Rastogi; Arunangshu Chakraborty; Subir Sinha
Journal:  Indian J Anaesth       Date:  2019-02

6.  Effect of different types of laryngeal mask airway placement on the right internal jugular vein: A prospective randomized controlled trial.

Authors:  Jing-Jing Zhang; Zong-Yang Qu; Zhen Hua; Ming-Zhang Zuo; Hong-Ye Zhang
Journal:  World J Clin Cases       Date:  2019-12-26       Impact factor: 1.337

7.  Ultrasonographic Assessment of Anatomic Relationship Between the Internal Jugular Vein and the Common Carotid Artery in Infants and Children After ETT or LMA Insertion: A Prospective Observational Study.

Authors:  Yipeng Du; Jin Wang; Limin Jin; Chunping Li; Haichun Ma; Su Dong
Journal:  Front Pediatr       Date:  2020-10-29       Impact factor: 3.418

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.