High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters.

E G Yukihara1, E M Yoshimura, T D Lindstrom, S Ahmad, K K Taylor, G Mardirossian.   

Abstract

The potential of using the optically stimulated luminescence (OSL) technique with aluminium oxide (Al(2)O(3):C) dosimeters for a precise and accurate estimation of absorbed doses delivered by high-energy photon beams was investigated. This study demonstrates the high reproducibility of the OSL measurements and presents a preliminary determination of the depth-dose curve in water for a 6 MV photon beam from a linear accelerator. The uncertainty of a single OSL measurement, estimated from the variance of a large sample of dosimeters irradiated with the same dose, was 0.7%. In the depth-dose curve obtained using the OSL technique, the difference between the measured and expected doses was < or =0.7% for depths between 1.5 and 10 cm, and 1.1% for a depth of 15 cm. The readout procedure includes a normalization of the response of the dosimeter with respect to a reference dose in order to eliminate variations in the dosimeter mass, dosimeter sensitivity, and the reader's sensitivity. This may be relevant for quality assurance programmes, since it simplifies the requirements in terms of personnel training to achieve the precision and accuracy necessary for radiotherapy applications. We concluded that the OSL technique has the potential to be reliably incorporated in quality assurance programmes and dose verification.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16306656     DOI: 10.1088/0031-9155/50/23/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Characterization of the nanoDot OSLD dosimeter in CT.

Authors:  Sarah B Scarboro; Dianna Cody; Paola Alvarez; David Followill; Laurence Court; Francesco C Stingo; Di Zhang; Michael McNitt-Gray; Stephen F Kry
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Radioprotective effects produced by the condensation of plasmid DNA with avidin and biotinylated gold nanoparticles.

Authors:  Christopher C Perry; Sarah M Urata; Melissa Lee; Joe A Aguilera; Jamie R Milligan
Journal:  Radiat Environ Biophys       Date:  2012-07-24       Impact factor: 1.925

3.  Improved simultaneous LET and dose measurements in proton therapy.

Authors:  Jeppe Brage Christensen; Michele Togno; Lily Bossin; Oskari Ville Pakari; Sairos Safai; Eduardo Gardenali Yukihara
Journal:  Sci Rep       Date:  2022-05-18       Impact factor: 4.996

4.  Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

Authors:  Jerimy C Polf; Rajesh Panthi; Dennis S Mackin; Matt McCleskey; Antti Saastamoinen; Brian T Roeder; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-08-06       Impact factor: 3.609

5.  Response of Nanodot Optically Stimulated Luminescence Dosimeters to Therapeutic Electron Beams.

Authors:  Y Retna Ponmalar; Ravikumar Manickam; S Sathiyan; K M Ganesh; R Arun; Henry Finlay Godson
Journal:  J Med Phys       Date:  2017 Jan-Mar

6.  Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study.

Authors:  Fadil Akyol; Neslihan Sarigul; Mete Yeginer; Yagiz Yedekci; Haluk Utku
Journal:  J Med Phys       Date:  2019 Jan-Mar

7.  Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications.

Authors:  A S Pradhan; J I Lee; J L Kim
Journal:  J Med Phys       Date:  2008-07

8.  Optically stimulated luminescent dosimetry for high dose rate brachytherapy.

Authors:  Christopher Jason Tien; Robert Ebeling; Jessica R Hiatt; Bruce Curran; Edward Sternick
Journal:  Front Oncol       Date:  2012-08-06       Impact factor: 6.244

9.  Evaluation of equivalent dose from neutrons and activation products from a 15-MV X-ray LINAC.

Authors:  Isra Israngkul-Na-Ayuthaya; Sivalee Suriyapee; Phongpheath Pengvanich
Journal:  J Radiat Res       Date:  2015-08-11       Impact factor: 2.724

10.  A methodology for on-board CBCT imaging dose using optically stimulated luminescence detectors.

Authors:  Noor Mail; Muhammad Yusuf; Nazeeh Alothmany; A Abdulrahman Kinsara; Fahad Abdulkhaliq; Suliman M Ghamdi; Abdelhamid Saoudi
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.