Literature DB >> 16306646

Dosimetric characteristics of the Elekta Beam Modulator.

I Patel1, A G Glendinning, M C Kirby.   

Abstract

The dosimetric characteristics of a production pilot multi-leaf collimator (Elekta Beam Modulator, Elekta Oncology Systems, Crawley, UK) having a 4 mm leaf width (at isocentre) have been investigated. Characteristics explored included leaf bank set-up, penumbra width (80-20%) as a function of leaf position, leaf positioning reproducibility, interleaf leakage and leaf transmission. The penumbra values for leaf ends were measured to be between 4.2 and 4.8 mm for various large rectangular fields studied using Kodak X-omat V film at isocentre (1.5 cm deep). Similar films were taken with a standard 1 cm width multi-leaf collimator (MLC) and the penumbra for leaf ends was found to range from 4.3 to 5.2 mm. Other results showed that the rounded leaf tip provided tight control of the penumbra across the leaves' full range of travel. The positioning of the leaves was within a 0.5 mm range when approaching from the same direction. The maximum interleaf leakage was found to be 1.7% and the average leaf transmission less than 1.0%. No major differences were observed in leakage and transmission with changing gantry angle.

Mesh:

Year:  2005        PMID: 16306646     DOI: 10.1088/0031-9155/50/23/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Volumetric image-guided highly conformal radiotherapy of the prostate bed: Toxicity analysis.

Authors:  Gianluca Ingrosso; Alessandra Carosi; Daniela di Cristino; Elisabetta Ponti; Andrea Lancia; Alessandra Murgia; Claudia Bruni; Pasquale Morelli; Franca Pietrasanta; Riccardo Santoni
Journal:  Rep Pract Oncol Radiother       Date:  2016-11-24

2.  Investigation of two linear accelerator head designs for treating brain metastases with hypofractionated volumetric-modulated arc radiotherapy.

Authors:  Mark Ruschin; Arjun Sahgal; Sara Iradji; Hany Soliman; Claudia Leavens; Young Lee
Journal:  Br J Radiol       Date:  2016-04-13       Impact factor: 3.039

3.  Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer.

Authors:  Youling Gong; Shichao Wang; Lin Zhou; Yongmei Liu; Yong Xu; You Lu; Sen Bai; Yuchuan Fu; Qingfeng Xu; Qingfeng Jiang
Journal:  Radiat Oncol       Date:  2010-07-15       Impact factor: 3.481

4.  Single arc volumetric-modulated arc therapy is sufficient for nasopharyngeal carcinoma: a dosimetric comparison with dual arc VMAT and dynamic MLC and step-and-shoot intensity-modulated radiotherapy.

Authors:  Zhong-Hua Ning; Jin-Ming Mu; Jian-Xue Jin; Xiao-Dong Li; Qi-Lin Li; Wen-Dong Gu; Jin Huang; Yang Han; Hong-Lei Pei
Journal:  Radiat Oncol       Date:  2013-10-14       Impact factor: 3.481

5.  Investigation of irradiated volume in linac-based brain hypo-fractionated stereotactic radiotherapy.

Authors:  Mark Ruschin; Arjun Sahgal; Hany Soliman; Sten Myrehaug; May Tsao; Collins Yeboah; Arman Sarfehnia; Brige Chugh; Alex Kiss; Young Lee
Journal:  Radiat Oncol       Date:  2017-07-14       Impact factor: 3.481

6.  Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs.

Authors:  Lori A Young; Fei Yang; Ning Cao; Juergen Meyer
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

7.  Dosimetric sensitivity of leaf width on volumetric modulated arc therapy plan quality: an objective approach.

Authors:  Ghulam Murtaza; Muhammad Shamshad; Munir Ahmed; Shahid Mehmood; Ehsan Ullah Khan
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22

8.  Comparison of stereotactic plans for brain tumors with two different multileaf collimating systems.

Authors:  Livia Marrazzo; Margherita Zani; Stefania Pallotta; Daniela Greto; Silvia Scoccianti; Cinzia Talamonti; Giampaolo Biti; Marta Bucciolini
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

9.  Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator.

Authors:  James L Bedford; Michael D R Thomas; Gregory Smyth
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.