Literature DB >> 16303491

Subjective and objective measures of corneal staining related to multipurpose care systems.

Nicola Pritchard1, Graeme Young, Sarah Coleman, Chris Hunt.   

Abstract

An objective, digital-imaging method of measuring corneal staining was evaluated in 24 subjects wearing soft contact lenses. The method was used to compare the clinical performance of common multipurpose care systems (MPS) for soft contact lens care. Subjects used three different MPS, one containing polyquaternium-1 (PQ) and two containing polyhexanide (PX1 and PX2), for 2 weeks in a randomised, single-masked (investigator) crossover study. Corneal staining induced with the three MPS was analysed using an image-processing program (ImageTool, UTHSCSA Version 2, University of Texas, USA). Conjunctival hyperaemia and papillae were also evaluated. The intraclass correlation coefficient was similar with image analysis to that of investigator grading (0.876, 0.879, respectively). Significant differences in staining response were detected using the objective method. There was significantly less staining area with polyquaternium-1 (PQ) than polyhexanide (PQ: 0.12 mm(2), PX2: 0.91 mm(2)). Inferior palpebral papillae were significantly greater with PX2 than with PQ (1.0, 0.7 (0-4), respectively). The technique was shown to be an effective method of evaluating different corneal staining responses. Bilateral corneal staining in three or more quadrants is useful in the diagnosis of MPS-related staining.

Entities:  

Year:  2003        PMID: 16303491     DOI: 10.1016/S1367-0484(02)00083-8

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  10 in total

1.  Sensitivity and reliability of objective image analysis compared to subjective grading of bulbar hyperaemia.

Authors:  Rachael Claire Peterson; James Stuart Wolffsohn
Journal:  Br J Ophthalmol       Date:  2007-05-02       Impact factor: 4.638

2.  Fluorescein punctate staining traced to superficial corneal epithelial cells by impression cytology and confocal microscopy.

Authors:  Maryam Mokhtarzadeh; Richard Casey; Ben J Glasgow
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-05       Impact factor: 4.799

3.  Treatment, material, care, and patient-related factors in contact lens-related dry eye.

Authors:  Padmapriya Ramamoorthy; Loraine T Sinnott; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2008-08       Impact factor: 1.973

4.  In the aftermath of the Fusarium keratitis outbreak: What have we learned?

Authors:  Arthur B Epstein
Journal:  Clin Ophthalmol       Date:  2007-12

5.  A novel scale for describing corneal staining.

Authors:  Jill Woods; Jalaiah Varikooty; Desmond Fonn; Lyndon W Jones
Journal:  Clin Ophthalmol       Date:  2018-11-19

6.  Multimodal Assessment of Corneal Erosions Using Optical Coherence Tomography and Automated Grading of Fluorescein Staining in a Rabbit Dry Eye Model.

Authors:  Ifat Sher; Adi Tzameret; Alicja M Szalapak; Tomer Carmeli; Estela Derazne; Noa Avni-Zauberman; Arie L Marcovich; Guy Ben Simon; Ygal Rotenstreich
Journal:  Transl Vis Sci Technol       Date:  2019-02-28       Impact factor: 3.283

7.  Assessment of Corneal Fluorescein Staining in Different Dry Eye Subtypes Using Digital Image Analysis.

Authors:  Marc Pellegrini; Federic Bernabei; Fabian Moscardelli; Ald Vagge; Riccard Scotto; Cristin Bovone; Vincenz Scorcia; Giusepp Giannaccare
Journal:  Transl Vis Sci Technol       Date:  2019-12-12       Impact factor: 3.283

8.  Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens.

Authors:  Nery García-Porta; Laura Rico-del-Viejo; Helena Ferreira-Neves; Sofia C Peixoto-de-Matos; Antonio Queirós; José M González-Méijome
Journal:  Biomed Res Int       Date:  2015-03-31       Impact factor: 3.411

9.  Tear cytokine response to multipurpose solutions for contact lenses.

Authors:  Carolyn M Kalsow; William T Reindel; Mohinder M Merchea; Kirk M Bateman; Joseph T Barr
Journal:  Clin Ophthalmol       Date:  2013-06-28

10.  Semi-MsST-GAN: A Semi-Supervised Segmentation Method for Corneal Ulcer Segmentation in Slit-Lamp Images.

Authors:  Tingting Wang; Meng Wang; Weifang Zhu; Lianyu Wang; Zhongyue Chen; Yuanyuan Peng; Fei Shi; Yi Zhou; Chenpu Yao; Xinjian Chen
Journal:  Front Neurosci       Date:  2022-01-04       Impact factor: 4.677

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.