Innovative technologies for the assessment of cardiovascular medical devices: state-of-the-art techniques for artificial heart valve testing.

Mauro Grigioni1, Carla Daniele, Giuseppe D'Avenio, Umberto Morbiducci, Costantino Del Gaudio, Mara Abbate, David Di Meo.   

Abstract

Prosthetic heart valves (PHVs) are engineered devices used for replacing diseased natural cardiac valves. This article presents several investigational techniques for the evaluation of the performance of these clinical devices, whose implantation is not completely free of drawbacks. The state-of-the-art in the technological approach for PHV testing is addressed. As the fluid dynamics of PHVs are particularly complex, the main focus will be on experimental velocimetric techniques and computational analysis. A methodology for the analysis of the valve's signature, in terms of its characteristic sound in the opening and closing phases, is also presented. The aforementioned techniques are necessary to guarantee an operational life of the implanted device as free as possible from clinical complications. It can be realistically expected that this characterization will help designers in improving PHV performance.

Entities:  

Mesh:

Year:  2004        PMID: 16293012     DOI: 10.1586/17434440.1.1.81

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  4 in total

1.  Near valve flows and potential blood damage during closure of a bileaflet mechanical heart valve.

Authors:  L H Herbertson; S Deutsch; K B Manning
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

2.  Automatic segmentation and tracking of biological prosthetic heart valves.

Authors:  Maryam Alizadeh; Melissa Cote; Alexandra Branzan Albu
Journal:  J Med Imaging (Bellingham)       Date:  2021-02-12

3.  Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve.

Authors:  Francesca Maria Susin; Stefania Espa; Riccardo Toninato; Stefania Fortini; Giorgio Querzoli
Journal:  Biomed Eng Online       Date:  2017-02-16       Impact factor: 2.819

4.  Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves.

Authors:  Ovandir Bazan; Jayme Pinto Ortiz; Francisco Ubaldo Vieira; Reinaldo Wilson Vieira; Nilson Antunes; Fabio Bittencourt Dutra Tabacow; Eduardo Tavares Costa; Orlando Petrucci
Journal:  Rev Bras Cir Cardiovasc       Date:  2013 Oct-Dec