Literature DB >> 16286613

Dynamic intraocular pressure measurements during vitrectomy.

Louise C Moorhead1, Thomas W Gardner, H Michael Lambert, Ronan E O'Malley, Arthur W Willis, Louis S Meharg, William D Moorhead.   

Abstract

OBJECTIVES: To directly measure dynamic intraocular pressure (IOP) during vitrectomy and to determine whether disposable pressure transducers placed in the infusion line can indirectly measure with accuracy the dynamic IOP during vitrectomy.
METHODS: Experimental clinical study of 10 patients undergoing vitrectomy. Dynamic IOP was sampled via an extra pars plana incision with a catheter transducer equipped to measure direct IOP during vitrectomy by attaching a metal flange near the pressure-sensing tip. Disposable blood pressure transducers were placed in the infusion tubing fluid path to determine the IOP by indirect means. During various maneuvers of vitrectomy including air-fluid exchange and gas-forced infusion, pressure measurements were taken simultaneously from the indwelling pressure transducer and the disposable blood pressure sensors in the infusion line.
RESULTS: The directly measured IOP varied between 0 and 120 mm Hg during vitrectomy. During fluid flow, the indirectly measured IOP, calculated from the infusion line pressures, accurately corresponded with the directly measured IOP.
CONCLUSIONS: Closed vitrectomy causes wide fluctuations in IOP. The IOP can be accurately measured during fluid flow with inline sensors.

Entities:  

Mesh:

Year:  2005        PMID: 16286613     DOI: 10.1001/archopht.123.11.1514

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  5 in total

1.  Effect of simulated dynamic intraocular pressure on retinal thickness measured by optical coherence tomography after cataract surgery.

Authors:  Ding Chen; Jun Zhu; Jin Li; Xi-Xia Ding; Fan Lu; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-12-18       Impact factor: 1.779

2.  Elevated intraocular pressure causes cellular and molecular retinal injuries, advocating a more moderate intraocular pressure setting during phacoemulsification surgery.

Authors:  Zhenni Zhao; Xiaowei Yu; Xue Yang; Jiamin Zhang; Dandan Zhang; Nannan Sun; Zhigang Fan
Journal:  Int Ophthalmol       Date:  2020-07-28       Impact factor: 2.031

3.  Dynamic Pressure Measurements During Vitrectomy in a Model of the Eye.

Authors:  Irene Nepita; Alessandro Stocchino; Andrea Dodero; Maila Castellano; Mariantonia Ferrara; Mario R Romano; Rodolfo Repetto
Journal:  Transl Vis Sci Technol       Date:  2022-05-02       Impact factor: 3.048

4.  Additive Manufacturing of a Miniature Functional Trocar for Eye Surgery.

Authors:  Kirsten Lussenburg; Marta Scali; Aimée Sakes; Paul Breedveld
Journal:  Front Med Technol       Date:  2022-02-17

5.  Impact of fluidic parameters during phacoemulsification on the anterior vitreous face behavior: Experimental study.

Authors:  Vaishali Vasavada; Samaresh Srivastava; Viraj Vasavada; Shail Vasavada; Abhay R Vasavada; Aditya Sudhalkar; Alper Bilgic
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

  5 in total