Literature DB >> 16285395

Harmonic decomposition in PDE-based denoising technique for magnetic resonance electrical impedance tomography.

Byung Il Lee1, Suk-Ho Lee, Tae-Seong Kim, Ohin Kwon, Eung Je Woo, Jin Keun Seo.   

Abstract

Recent progress in magnetic resonance electrical impedance tomography (MREIT) research via simulation and biological tissue phantom studies have shown that conductivity images with higher spatial resolution and accuracy are achievable. In order to apply MREIT to human subjects, one of the important remaining problems to be solved is to reduce the amount of the injection current such that it meets the electrical safety regulations. However, by limiting the amount of the injection current according to the safety regulations, the measured MR data such as the z-component of magnetic flux density Bz in MREIT tend to have low SNR and get usually degraded in their accuracy due to the nonideal data acquisition system of an MR scanner. Furthermore, numerical differentiations of the measured Bz required by the conductivity image reconstruction algorithms tend to further deteriorate the quality and accuracy of the reconstructed conductivity images. In this paper, we propose a denoising technique that incorporates a harmonic decomposition. The harmonic decomposition is especially suitable for MREIT due to the physical characteristics of Bz. It effectively removes systematic and random noises, while preserving important key features in the MR measurements, so that improved conductivity images can be obtained. The simulation and experimental results demonstrate that the proposed denoising technique is effective for MREIT, producing significantly improved quality of conductivity images. The denoising technique will be a valuable tool in MREIT to reduce the amount of the injection current when it is combined with an improved MREIT pulse sequence.

Entities:  

Mesh:

Year:  2005        PMID: 16285395     DOI: 10.1109/TBME.2005.856258

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  High field MREIT: setup and tissue phantom imaging at 11 T.

Authors:  Rosalind Sadleir; Samuel Grant; Sung Uk Zhang; Suk Hoon Oh; Byung Il Lee; Eung Je Woo
Journal:  Physiol Meas       Date:  2006-04-24       Impact factor: 2.833

2.  Can high-field MREIT be used to directly detect neural activity? Theoretical considerations.

Authors:  R J Sadleir; S C Grant; E J Woo
Journal:  Neuroimage       Date:  2010-04-09       Impact factor: 6.556

3.  MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

Authors:  V E Arpinar; M J Hamamura; E Degirmenci; L T Muftuler
Journal:  Phys Med Biol       Date:  2012-06-08       Impact factor: 3.609

4.  Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions.

Authors:  Munish Chauhan; Rohini Vidya Shankar; Neeta Ashok Kumar; Vikram D Kodibagkar; Rosalind Sadleir
Journal:  Magn Reson Med       Date:  2017-02-16       Impact factor: 4.668

5.  Accelerating acquisition strategies for low-frequency conductivity imaging using MREIT.

Authors:  Yizhuang Song; Jin Keun Seo; Munish Chauhan; Aprinda Indahlastari; Neeta Ashok Kumar; Rosalind Sadleir
Journal:  Phys Med Biol       Date:  2018-02-13       Impact factor: 3.609

6.  CoReHA 2.0: a software package for in vivo MREIT experiments.

Authors:  Kiwan Jeon; Chang-Ock Lee
Journal:  Comput Math Methods Med       Date:  2013-02-24       Impact factor: 2.238

7.  Numerical simulations of MREIT conductivity imaging for brain tumor detection.

Authors:  Zi Jun Meng; Saurav Z K Sajib; Munish Chauhan; Rosalind J Sadleir; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Journal:  Comput Math Methods Med       Date:  2013-04-29       Impact factor: 2.238

8.  Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions.

Authors:  Munish Chauhan; Woo Chul Jeong; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2013-08-27       Impact factor: 2.819

9.  Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter.

Authors:  Tong In Oh; Hyung Joong Kim; Woo Chul Jeong; Hun Wi; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2014-06-26       Impact factor: 2.819

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.