Literature DB >> 16269065

In vivo assessment of emphysema in mice by high resolution X-ray microtomography.

A A Postnov1, K Meurrens, H Weiler, D Van Dyck, H Xu, P Terpstra, N M De Clerck.   

Abstract

High resolution X-ray microtomography (micro-CT) was used for the detection of emphysema in live mice. Emphysema was induced in C57BL/6 J mice by intratracheal instillation of different amounts of porcine pancreatic elastase. This emphysema could be clearly detected by micro-CT seven weeks post-treatment: analysis of the whole data set of virtual cross-sections showed the presence of a dose-dependent level of emphysema.

Entities:  

Mesh:

Year:  2005        PMID: 16269065     DOI: 10.1111/j.1365-2818.2005.01510.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  15 in total

1.  Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response.

Authors:  Fabian Eisa; Robert Brauweiler; Martin Hupfer; Tristan Nowak; Laura Lotz; Inge Hoffmann; David Wachter; Ralf Dittrich; Matthias W Beckmann; Gregor Jost; Hubertus Pietsch; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-11-10       Impact factor: 5.315

2.  Evaluation of micro-CT for emphysema assessment in mice: comparison with non-radiological techniques.

Authors:  Xabier Artaechevarria; David Blanco; Gabriel de Biurrun; Mario Ceresa; Daniel Pérez-Martín; Gorka Bastarrika; Juan P de Torres; Javier J Zulueta; Luis M Montuenga; Carlos Ortiz-de-Solorzano; Arrate Munoz-Barrutia
Journal:  Eur Radiol       Date:  2010-10-18       Impact factor: 5.315

3.  Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

Authors:  Cristian T Badea; Samuel M Johnston; Ergys Subashi; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice.

Authors:  Scott Shofer; Cristian Badea; Scott Auerbach; David A Schwartz; G Allan Johnson
Journal:  Exp Lung Res       Date:  2007 Apr-May       Impact factor: 2.459

5.  Possibilities and limits of X-ray microtomography for in vivo and ex vivo detection of vascular calcifications.

Authors:  A A Postnov; P C D'Haese; E Neven; N M De Clerck; V P Persy
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-11       Impact factor: 2.357

Review 6.  Whole animal imaging.

Authors:  Gurpreet Singh Sandhu; Luis Solorio; Ann-Marie Broome; Nicolas Salem; Jeff Kolthammer; Tejas Shah; Chris Flask; Jeffrey L Duerk
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2010 Jul-Aug

7.  Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging.

Authors:  Eman Namati; Jacqueline Thiesse; Jessica C Sieren; Alan Ross; Eric A Hoffman; Geoffrey McLennan
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  A new method for respiratory gating during microcomputed tomography of lung in mice.

Authors:  Evan M Johnson; Roger E Price; Jonathan M Kurie; Belinda S Rivera; Dianna D Cody
Journal:  J Am Assoc Lab Anim Sci       Date:  2008-07       Impact factor: 1.232

Review 9.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

Review 10.  In vivo small-animal imaging using micro-CT and digital subtraction angiography.

Authors:  C T Badea; M Drangova; D W Holdsworth; G A Johnson
Journal:  Phys Med Biol       Date:  2008-08-29       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.