Literature DB >> 16268986

Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI.

Andreas Kjaer1, Anne-Mette Lebech, Birger Hesse, Claus Leth Petersen.   

Abstract

BACKGROUND: Right ventricular (RV) function is of interest in an array of cardiopulmonary diseases. First-pass radionuclide ventriculography (FP), gated blood-pool single photon emission tomography (GBPS) and cardiac magnetic resonance imaging (MRI) are three currently used non-invasive methods for evaluation of right-sided cardiac function. The aim of our study was to compare the agreement between these methods when measuring right-sided cardiac function.
METHODS: Twenty-four healthy volunteers were included. Mean age was 44 years (range: 25-60) and 29% were females. All participants had FP, GBPS and breath-hold cine MRI performed according to standard protocols.
RESULTS: Normal ranges for RV ejection fraction (RVEF) defined as mean +/- 2SD were 0.49-0.72, 0.44-0.66 and 0.40-0.69 when measured by MRI, FP and GBPS respectively. Bland-Altman analysis showed a mean difference (bias) between MRI and FP of 0.05 (95% CI: 0.03-0.08) and of 0.06 (95% CI: 0.02-0.10) between MRI and GBPS. No systematic bias was found between FP and GBPS. Normal values for RV end-diastolic volume index (RVEDVI) were 37-95 and 29-91 ml m(-2) when measured by MRI and GBPS respectively. The mean difference between RVEDVI was 6 ml m(-2) (95% CI: 0-11).
CONCLUSIONS: (i) Normal values of RVEF differ between MRI, FP and GBPS with wide limits of agreement, accordingly it is difficult to evaluate changes over time if measured by different methods, (ii) RV volumes are in the same range when measured by MRI or GBPS but with wide limits of agreement, and (iii) if MRI is considered gold standard then FP is more accurate than GBPS for RVEF measurements.

Entities:  

Mesh:

Year:  2005        PMID: 16268986     DOI: 10.1111/j.1475-097X.2005.00635.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  14 in total

Review 1.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

2.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

3.  A comparison of right ventricular volume change during systole obtained using the monoplane Simpson's method in two-dimensional echocardiographic apical four-chamber view with right ventricular volume change obtained using a prisma model reflecting the systolic long-axis shortening of the right ventricle of the heart: A pilot study.

Authors:  K Loiske; K Emilsson
Journal:  Exp Clin Cardiol       Date:  2008

4.  Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting.

Authors:  Laurent Dercle; Monia Ouali; Pierre Pascal; Thomas Giraudmaillet; Roland Chisin; Olivier Lairez; Marie-Agnès Marachet; Hervé Rousseau; Delphine Bastié; Fayçal Ben Bouallègue; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

5.  Is TOMPOOL (gated blood-pool SPECT processing software) accurate to diagnose right and left ventricular dysfunction in a clinical setting?

Authors:  Laurent Dercle; Thomas Giraudmaillet; Pierre Pascal; Olivier Lairez; Roland Chisin; Marie-Agnès Marachet; Monia Ouali; Hervé Rousseau; Delphine Bastié; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2014-05-30       Impact factor: 5.952

6.  Is MRI the preferred method for evaluating right ventricular size and function in patients with congenital heart disease?: MRI is the preferred method for evaluating right ventricular size and function in patients with congenital heart disease.

Authors:  Tal Geva
Journal:  Circ Cardiovasc Imaging       Date:  2014-01       Impact factor: 7.792

7.  Cardiac Magnetic Resonance Evaluation of Left Ventricular Myocardial Strain in Pulmonary Hypertension.

Authors:  Kimberly Kallianos; Gabriel C Brooks; Kanae Mukai; Florent Seguro de Carvalho; Jing Liu; David M Naeger; Teresa De Marco; Karen G Ordovas
Journal:  Acad Radiol       Date:  2017-08-31       Impact factor: 3.173

8.  Evaluation of right ventricular volume and ejection fraction by gated (18)F-FDG PET in patients with pulmonary hypertension: comparison with cardiac MRI and CT.

Authors:  Lei Wang; Yan Zhang; Chaowu Yan; Jianguo He; Changming Xiong; Shihua Zhao; Wei Fang
Journal:  J Nucl Cardiol       Date:  2013-01-26       Impact factor: 5.952

9.  Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera.

Authors:  Christian Haarmark; Christine Haase; Maria Maj Jensen; Bo Zerahn
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

10.  Assessing the utility of pre-operative first pass radionuclide angiography to predict right ventricular failure post left ventricular assist device implantation.

Authors:  Matthew C Konerman; Venkatesh L Murthy; Vaiibhav N Patel; Marty C Tam; Maryse Palardy
Journal:  J Nucl Cardiol       Date:  2019-09-23       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.