Literature DB >> 16266118

Real-time DMLC IMRT delivery for mobile and deforming targets.

Lech Papiez1, Dharanipathy Rangaraj, Paul Keall.   

Abstract

In numerous cases of radiotherapy delivery to moving targets, simplifying assumptions of identical pattern of motions of tissue for each fraction are not satisfied. Therefore, algorithms capable to respond in real time to motions of target registered at treatment should be developed to improve the precision of radiation intensity delivery. The DMLC delivery of predetermined intensity maps to moving and deforming targets in real time is developed in this paper. Algorithms are constructed so that constraints on maximum admissible speed of leaves are preserved during delivery. A sequence of examples is presented to illustrate behavior of leaf trajectories for representative cases of [dynamic multileaf collimator] (DMLC) [intensity modulated radiation therapy] (IMRT) real-time delivery. The examples presented show real-time deliveries to targets moving as rigid bodies and targets deforming uniformly over their volumes. Examples are admitting random perturbations of predefined target motions that are time dependent only, i.e., target motion perturbations are identical for all target points.

Entities:  

Mesh:

Year:  2005        PMID: 16266118     DOI: 10.1118/1.1987967

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Breathing-synchronized delivery: a potential four-dimensional tomotherapy treatment technique.

Authors:  Tiezhi Zhang; Weiguo Lu; Gustavo H Olivera; Harry Keller; Robert Jeraj; Rafael Manon; Minesh Mehta; Thomas R Mackie; Bhudatt Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-14       Impact factor: 7.038

2.  Target tracking using DMLC for volumetric modulated arc therapy: a simulation study.

Authors:  Baozhou Sun; Dharanipathy Rangaraj; Lech Papiez; Swetha Oddiraju; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

3.  Characterization of free breathing patterns with 5D lung motion model.

Authors:  Tianyu Zhao; Wei Lu; Deshan Yang; Sasa Mutic; Camille E Noel; Parag J Parikh; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

4.  Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.

Authors:  Wei Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Yu-Hui Chang; Zhifei Wen; Jiajian Shen; Joshua B Stoker; Xiaoning Ding; Yanle Hu; Narayan Sahoo; Michael G Herman; Carlos Vargas; Sameer Keole; William Wong; Martin Bues
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-10       Impact factor: 7.038

5.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

6.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator.

Authors:  Yuanyuan Ge; Ricky T O'Brien; Chun-Chien Shieh; Jeremy T Booth; Paul J Keall
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

8.  A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery.

Authors:  Yelin Suh; Elisabeth Weiss; Hualiang Zhong; Mirek Fatyga; Jeffrey V Siebers; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

9.  On the accuracy of a moving average algorithm for target tracking during radiation therapy treatment delivery.

Authors:  Rohini George; Yelin Suh; Martin Murphy; Jeffrey Williamson; Elizabeth Weiss; Paul Keall
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

10.  Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters.

Authors:  Joubin Nasehi Tehrani; Yin Yang; Rene Werner; Wei Lu; Daniel Low; Xiaohu Guo; Jing Wang
Journal:  Phys Med Biol       Date:  2015-11-04       Impact factor: 3.609