Literature DB >> 16264255

The point spread function of spiral CT.

Gil Schwarzband1, Nahum Kiryati.   

Abstract

Computed tomography (CT) scanners are usually described by their in-plane resolution and slice-sensitivity profile (SSP). Other imaging systems are characterized by their point spread function (PSF). The PSF is an excellent basis for the analysis, design and enhancement of imaging systems. The 3D PSF of CT systems has rarely been considered, and has usually been approximated by a 3D Gaussian. We present mathematical analysis of the PSF of single-slice and multi-slice fan-beam and cone-beam CT, for major reconstruction algorithms. We show that the PSF has a complicated, non-separable 3D shape. It is anisotropic in the xy plane and twisted in the z direction. Furthermore, the PSF is space variant in all three axes. In particular, it rotates as the input impulse function moves in the z direction. The PSF may also have effective discontinuities that can lead to streaking artefacts. Indirect measurements of the PSF can be misleading. We support the theoretical results by direct experimental measurements of the PSF.

Mesh:

Year:  2005        PMID: 16264255     DOI: 10.1088/0031-9155/50/22/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry.

Authors:  Ayumu Funaki; Masaki Ohkubo; Shinichi Wada; Kohei Murao; Toru Matsumoto; Shinji Niizuma
Journal:  Radiol Phys Technol       Date:  2012-03-25

2.  Imaging of small spherical structures in CT: simulation study using measured point spread function.

Authors:  Masaki Ohkubo; Shinichi Wada; Masayuki Kunii; Toru Matsumoto; Kanae Nishizawa
Journal:  Med Biol Eng Comput       Date:  2007-11-10       Impact factor: 2.602

3.  Airway wall attenuation: a biomarker of airway disease in subjects with COPD.

Authors:  George R Washko; Mark T Dransfield; Raúl San José Estépar; Alejandro Diaz; Shin Matsuoka; Tsuneo Yamashiro; Hiroto Hatabu; Edwin K Silverman; William C Bailey; John J Reilly
Journal:  J Appl Physiol (1985)       Date:  2009-04-30

4.  Bronchial Cartilage Assessment with Model-Based GAN Regressor.

Authors:  Pietro Nardelli; George R Washko; Raúl San José Estépar
Journal:  Med Image Comput Comput Assist Interv       Date:  2019-10-10

5.  Accurate Measurement of Airway Morphology on Chest CT Images.

Authors:  Pietro Nardelli; Mathias Buus Lanng; Cecilie Brochdorff Møller; Anne-Sofie Hendrup Andersen; Alex Skovsbo Jørgensen; Lasse Riis Østergaard; Raúl San José Estépar
Journal:  Image Anal Mov Organ Breast Thorac Images (2018)       Date:  2018-09-12

6.  Image analysis for cystic fibrosis: computer-assisted airway wall and vessel measurements from low-dose, limited scan lung CT images.

Authors:  Erkan U Mumcuoğlu; Frederick R Long; Robert G Castile; Metin N Gurcan
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

7.  Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Gabriel Ramos-Llordén; Raúl San José Estépar
Journal:  Med Phys       Date:  2021-09-14       Impact factor: 4.071

8.  Generative-based airway and vessel morphology quantification on chest CT images.

Authors:  Pietro Nardelli; James C Ross; Raúl San José Estépar
Journal:  Med Image Anal       Date:  2020-03-28       Impact factor: 8.545

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.